Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

University of Saskatchewan

$24,991.00

Negative sequence relay for sensitive winding fault detection in transformers

EF 2011-12

Résumé
An efficient protective relaying scheme using negative sequence currents for detecting minor internal turn-to-turn faults in power transformer windings would be developed in collaboration with Littelfuse Startco. The proposed scheme would make a magnitude comparison of the negative sequence currents on both sides of the transformer with the predefined settings; followed by a phase difference comparison between the two sides negative sequence currents. A prototype of the relay would also be developed using state-of-the-art digital signal processing (DSP) development board similar to the ones used by Startco. Hardware-in-the-loop testing would be used to verify the relaying algorithm (real-time simulator facility is already available in the power system laboratory at the University of Saskatchewan). The relay code would be made available to Startco and would also be implemented and tested using their relaying development platform. Startco supplies protective relays to number of mining installations in Canada. The machines in such installations are subject to very harsh operating conditions. Early detection of machine winding faults will help their clients to reduce downtime and increase productivity.
Programme
Engage Grants Program
Emplacement
Saskatchewan, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
425941-2011
Name nom
Gokaraju, Ramakrishna
Department département
Electrical & Computer Engineering
Organization id
16
Institution établissement
University of Saskatchewan
Province en
Saskatchewan
Province fr
Saskatchewan
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2011
Award amount
24991
Program id
EGP
Program nane en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
513
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Electrical and electronic machinery and equipment (including computer hardware)
Area of application fr
Machinerie et équipement électriques et électroniques (y compris matériel informatique)
Research subject code
2501
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Power systems
Research subject fr
Réseaux électriques
Partie
1
Nb partie
1
Application title
Negative sequence relay for sensitive winding fault detection in transformers
Keyword
NSERC
Application summary
An efficient protective relaying scheme using negative sequence currents for detecting minor internal turn-to-turn faults in power transformer windings would be developed in collaboration with Littelfuse Startco. The proposed scheme would make a magnitude comparison of the negative sequence currents on both sides of the transformer with the predefined settings; followed by a phase difference comparison between the two sides negative sequence currents. A prototype of the relay would also be developed using state-of-the-art digital signal processing (DSP) development board similar to the ones used by Startco. Hardware-in-the-loop testing would be used to verify the relaying algorithm (real-time simulator facility is already available in the power system laboratory at the University of Saskatchewan). The relay code would be made available to Startco and would also be implemented and tested using their relaying development platform. Startco supplies protective relays to number of mining installations in Canada. The machines in such installations are subject to very harsh operating conditions. Early detection of machine winding faults will help their clients to reduce downtime and increase productivity.