Grant: Research Tools and Instruments - Category 1 (<$150,000)
Ryerson University
$24,186.00
Wavefront sensor and high voltage multi-channel (>100) driver for adaptive optics based ophthalmoscopic imaging
EF 2011-12
Résumé
The application is to acquire funds to purchase a wavefront sensor and a multi-channel high voltage driver to support the research on ""Deformable Micromirror Based Adaptive Optics (AO) Technology for Ophthalmoscopic Imaging"". Early diagnosis and treatment of eye disease rely on high resolution retinal images. The current ophthalmoscopic imaging technology such as fundus cameras, the scanning laser ophthalmoscope (SLO) and the optical coherence tomography (OCT) ophthalmoscope can provide a macroscopic view of the living retina, but they do not have the transverse resolution needed to reveal retinal features on the spatial scale of single cells due to ocular aberrations caused by corneal surfaces and crystalline lenses. Deformable micromirror based Adaptive Optics (AO) is key to correcting these ocular aberrations, and thus improve the resolution of retinal imagining systems from the current 5~10 micrometers to 2~3 micrometers. A deformable micromirror based AO module able to correct ocular aberrations for vision science consists of a wavefront sensor to measure optical aberrations, a controller, a deformable micromirror driven by a multi-channel high voltage driver for correcting aberrations. The critical component of the deformable micromirror AO system is a large stroke out-of-plane micro actuator. An array of such actuators form the deformable micromirror. The applicants research groups have successfully developed a novel large stroke micro electrostatic actuator. The design of the deformable micromirror integrating 10x10 such large stroke actuators has been completed and sent for fabrication. Presently the applicants research groups are starting the integration of the deformable micromirror with the wavefront sensor and the multi-channel high voltage driver. The wavefront sensor and multi-channel high voltage driver are thus urgently needed to continue this multi-year project and to develop the micromirror AO module for ophthalmoscopic imaging. The successful development of such technology will significantly improve early diagnosis and treatment of eye disease such as glaucoma, which is the second most common cause of blindness in Canada and is affecting 300,000 Canadians.
Programme
Research Tools and Instruments - Category 1 (<$150,000)
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
422866-2012
Name nom
He, Siyuan
Department département
Mechanical and Industrial Engineering
Organization id
43
Institution établissement
Ryerson University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2011
Competition year année de concours
2012
Award amount
24186
Program id
EQPEQ
Program nane en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2109
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical systems and instrumentation
Research subject fr
Instrumentation et systèmes mécaniques
Partie
1
Nb partie
1
Application title
Wavefront sensor and high voltage multi-channel (>100) driver for adaptive optics based ophthalmoscopic imaging
Keyword
NSERC
Application summary
The application is to acquire funds to purchase a wavefront sensor and a multi-channel high voltage driver to support the research on ""Deformable Micromirror Based Adaptive Optics (AO) Technology for Ophthalmoscopic Imaging"". Early diagnosis and treatment of eye disease rely on high resolution retinal images. The current ophthalmoscopic imaging technology such as fundus cameras, the scanning laser ophthalmoscope (SLO) and the optical coherence tomography (OCT) ophthalmoscope can provide a macroscopic view of the living retina, but they do not have the transverse resolution needed to reveal retinal features on the spatial scale of single cells due to ocular aberrations caused by corneal surfaces and crystalline lenses. Deformable micromirror based Adaptive Optics (AO) is key to correcting these ocular aberrations, and thus improve the resolution of retinal imagining systems from the current 5~10 micrometers to 2~3 micrometers. A deformable micromirror based AO module able to correct ocular aberrations for vision science consists of a wavefront sensor to measure optical aberrations, a controller, a deformable micromirror driven by a multi-channel high voltage driver for correcting aberrations. The critical component of the deformable micromirror AO system is a large stroke out-of-plane micro actuator. An array of such actuators form the deformable micromirror. The applicants research groups have successfully developed a novel large stroke micro electrostatic actuator. The design of the deformable micromirror integrating 10x10 such large stroke actuators has been completed and sent for fabrication. Presently the applicants research groups are starting the integration of the deformable micromirror with the wavefront sensor and the multi-channel high voltage driver. The wavefront sensor and multi-channel high voltage driver are thus urgently needed to continue this multi-year project and to develop the micromirror AO module for ophthalmoscopic imaging. The successful development of such technology will significantly improve early diagnosis and treatment of eye disease such as glaucoma, which is the second most common cause of blindness in Canada and is affecting 300,000 Canadians.