Grant: Engage Grants Program
McGill University
$25,000.00
Clinical proxy for bone fracture risk in osteoporosis
EF 2017-18
Résumé
Today, clinical indicators of a possible bone fracture risk are vague - the current diagnostic criteria ofosteoporosis leave the autonomy and life quality of millions of people to chance. This proposal aims to resolvethe problem of characterization of spongy bone (most commonly affected by osteoporosis) based on clinicaltomographic imaging. This will be the first time that a new set of architectural parameters of spongy(trabecular) bone derived from a 3D image are used to provide a reliable prognosis to osteoporosis patients, asopposed to the traditionally-used bone mineral density or bone volume parameters. The proposal is based onthe recent discovery that healthy trabecular bone conforms to the topological principle of spanning maximal 3Dvolume with the minimal number of interconnected elements, akin to securing a sail mast to a boat deck with afew evenly spread ropes, rather than with the ropes pulling in one direction, or with a redundantly high numberof ropes. This topological principle reflects the adaptation of bone for effective re-distribution of diverse loadsand avoiding stress concentrations, both at the lowest metabolic cost. The topological descriptors of trabecularbone can be accessed via the novel inter-trabecular angle (ITA) analysis. This project will focus on detectionand analysis of variation of the topological parameters in healthy and osteoporotic trabecular bone. We havepreliminary evidence that such variation does exist and can be quantified. Following the definition of the rangebetween topologically stable and unstable configurations of trabecular bone, simulation of clinical imaging willbe carried out and an automated clinical application for medical tomography will be designed. The envisionedend result of this project will be an intuitive application ready for clinical validation and a supporting databaseof normal and pathological bone 3D images. This is especially relevant for developed countries where thehigh-longevity population succumbs to sedentary life style and metabolic diseases.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
514632-2017
Name nom
Song, Jun
Department département
Mining & Materials Engineering.
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
1208
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Materials sciences
Area of application fr
Sciences des matériaux
Research subject code
2006
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Biomaterials
Research subject fr
Biomatériaux
Partie
1
Nb partie
1
Application title
Clinical proxy for bone fracture risk in osteoporosis
Keyword
NSERC
Application summary
Today, clinical indicators of a possible bone fracture risk are vague - the current diagnostic criteria ofosteoporosis leave the autonomy and life quality of millions of people to chance. This proposal aims to resolvethe problem of characterization of spongy bone (most commonly affected by osteoporosis) based on clinicaltomographic imaging. This will be the first time that a new set of architectural parameters of spongy(trabecular) bone derived from a 3D image are used to provide a reliable prognosis to osteoporosis patients, asopposed to the traditionally-used bone mineral density or bone volume parameters. The proposal is based onthe recent discovery that healthy trabecular bone conforms to the topological principle of spanning maximal 3Dvolume with the minimal number of interconnected elements, akin to securing a sail mast to a boat deck with afew evenly spread ropes, rather than with the ropes pulling in one direction, or with a redundantly high numberof ropes. This topological principle reflects the adaptation of bone for effective re-distribution of diverse loadsand avoiding stress concentrations, both at the lowest metabolic cost. The topological descriptors of trabecularbone can be accessed via the novel inter-trabecular angle (ITA) analysis. This project will focus on detectionand analysis of variation of the topological parameters in healthy and osteoporotic trabecular bone. We havepreliminary evidence that such variation does exist and can be quantified. Following the definition of the rangebetween topologically stable and unstable configurations of trabecular bone, simulation of clinical imaging willbe carried out and an automated clinical application for medical tomography will be designed. The envisionedend result of this project will be an intuitive application ready for clinical validation and a supporting databaseof normal and pathological bone 3D images. This is especially relevant for developed countries where thehigh-longevity population succumbs to sedentary life style and metabolic diseases.