Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

University of Manitoba

$24,800.00

New approaches to detection and measurement of overhead conductor voltage

EF 2010-11

Résumé
Measuring the voltage level of an overhead conductor presents a challenging engineering problem that, at the core, reflects a very simple problem - the voltage is the difference in electric potential between two points, one of which is ""ground"". For the case of a high-voltage overhead conductor, providing an electrical ""path"" to ""ground"" is utterly unsafe. In order to measure the voltage on an energized or ""live"" overhead conductor, it is desirable to have a sensor or combination of sensors placed on the conductor itself that senses the electric field due to the voltage and/or any current in the conductor. Almost all approaches to this problem rely on large sensing devices that have to be manually lifted into the vicinity of the line, a dangerous operation which, ideally, should be avoided. This proposal seeks to re-visit the problem drawing on advances in solid-state device technology and novel materials. The goal is to develop a sensor that can be attached to the conductor when installed and then addressed through standard wireless protocols by someone standing on the ground (safely) underneath the line. As such, this sensor will need to be passive or, at worst, parasitic, i.e. a sensor that requires no power source other than the stimulus provided by the ""interrogation"" device held by the operator or, if small amounts of power are required, these can be obtained from the overhead conductor to which the device is attached. The technologies for wireless sensing and parasitic power-harvesting are sufficiently mature that the focus of the project is on developing some device designs that can, in the next stage, undergo prototype development and testing. This project will be undertaken in conjunction with Manitoba Hydro, whose motivation supporting in the study includes the prospect of enhanced worker safety and better monitoring capabilities for overhead conductors.
Programme
Engage Grants Program
Emplacement
Manitoba, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
405854-2010
Name nom
Oliver, Derek
Department département
Electrical and Computer Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2010
Award amount
24800
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
2501
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Power systems
Research subject fr
Réseaux électriques
Partie
1
Nb partie
1
Application title
New approaches to detection and measurement of overhead conductor voltage
Keyword
NSERC
Application summary
Measuring the voltage level of an overhead conductor presents a challenging engineering problem that, at the core, reflects a very simple problem - the voltage is the difference in electric potential between two points, one of which is ""ground"". For the case of a high-voltage overhead conductor, providing an electrical ""path"" to ""ground"" is utterly unsafe. In order to measure the voltage on an energized or ""live"" overhead conductor, it is desirable to have a sensor or combination of sensors placed on the conductor itself that senses the electric field due to the voltage and/or any current in the conductor. Almost all approaches to this problem rely on large sensing devices that have to be manually lifted into the vicinity of the line, a dangerous operation which, ideally, should be avoided. This proposal seeks to re-visit the problem drawing on advances in solid-state device technology and novel materials. The goal is to develop a sensor that can be attached to the conductor when installed and then addressed through standard wireless protocols by someone standing on the ground (safely) underneath the line. As such, this sensor will need to be passive or, at worst, parasitic, i.e. a sensor that requires no power source other than the stimulus provided by the ""interrogation"" device held by the operator or, if small amounts of power are required, these can be obtained from the overhead conductor to which the device is attached. The technologies for wireless sensing and parasitic power-harvesting are sufficiently mature that the focus of the project is on developing some device designs that can, in the next stage, undergo prototype development and testing. This project will be undertaken in conjunction with Manitoba Hydro, whose motivation supporting in the study includes the prospect of enhanced worker safety and better monitoring capabilities for overhead conductors.