Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of Waterloo

$22,300.00

Advanced composite dielectric materials for use in the transmision of electrical power by direct current

EF 2014-15

Résumé
Standard industry tests coupled with in-service experience have commonly been used to develop insulator designs for high voltage alternating current (HVAC) transmission lines. For the most part, conventional ceramic insulators have been used on HVAC transmission lines for the past 100 years or so. Today, insulators that are made from polymeric materials (polymer insulators) are gradually replacing the older ceramic insulators. Polymer insulators have been developed in this way for HVAC and are currently used in limited numbers on high voltage direct current (HVDC) transmission lines. In light of increased global interest in HVDC transmission, polymer insulators for HVDC have become an unknown entity, as no standard industry tests have been developed for HVDC. In this research program, polymer insulators for HVAC are assessed for use at HVDC using the standard tests developed for HVAC, but suitably modified for HVDC, both for suitability of polymeric material and insulator design evaluation in terms of being able to withstand the environmental conditions conducive to aging of polymeric materials. The research program will initially examine the inclined plane test (IPT) that has been developed specifically for AC and suitably modifying the test for DC. This step highlights the differences in aging mechanisms of polymeric materials, between AC and DC, and validates the use of AC polymeric insulation materials at DC. The electrowetting mechanism of surfaces, which is a major factor in aging of polymeric materials, is to be investigated and compared at AC, +DC and -DC. The two common polymeric materials for HVAC insulators, silicone rubber and ethylene propylene diene monomer, will be studied with various fillers and filler levels using the IPT at DC. Insulator design, for DC will be investigated in a salt-fog environment and existing designs for AC will be examined for use at DC at similar aging conditions. Modifications to insulator profile and material for optimum performance is expected to be the outcome of the research program.
Programme
Discovery Grants Program - Individual
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
1695-2013
Name nom
Cherney, Edward
Department département
Electrical & Computer Engineering
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2013
Award amount
22300
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
2516
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Energy conversion and distribution
Research subject fr
Conversion et distribution de l'énergie
Partie
2
Nb partie
5
Application title
Advanced composite dielectric materials for use in the transmision of electrical power by direct current
Keyword
NSERC
Application summary
Standard industry tests coupled with in-service experience have commonly been used to develop insulator designs for high voltage alternating current (HVAC) transmission lines. For the most part, conventional ceramic insulators have been used on HVAC transmission lines for the past 100 years or so. Today, insulators that are made from polymeric materials (polymer insulators) are gradually replacing the older ceramic insulators. Polymer insulators have been developed in this way for HVAC and are currently used in limited numbers on high voltage direct current (HVDC) transmission lines. In light of increased global interest in HVDC transmission, polymer insulators for HVDC have become an unknown entity, as no standard industry tests have been developed for HVDC. In this research program, polymer insulators for HVAC are assessed for use at HVDC using the standard tests developed for HVAC, but suitably modified for HVDC, both for suitability of polymeric material and insulator design evaluation in terms of being able to withstand the environmental conditions conducive to aging of polymeric materials. The research program will initially examine the inclined plane test (IPT) that has been developed specifically for AC and suitably modifying the test for DC. This step highlights the differences in aging mechanisms of polymeric materials, between AC and DC, and validates the use of AC polymeric insulation materials at DC. The electrowetting mechanism of surfaces, which is a major factor in aging of polymeric materials, is to be investigated and compared at AC, +DC and -DC. The two common polymeric materials for HVAC insulators, silicone rubber and ethylene propylene diene monomer, will be studied with various fillers and filler levels using the IPT at DC. Insulator design, for DC will be investigated in a salt-fog environment and existing designs for AC will be examined for use at DC at similar aging conditions. Modifications to insulator profile and material for optimum performance is expected to be the outcome of the research program.