Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of British Columbia

$17,000.00

SYMBIOM (Synergic inertial microsystems for bio-medical applications)

EF 2007-08

Résumé
The present research program is related to the development of an inertial sensor cluster for navigated surgery, complemented by other intelligent surgery tools. Medical navigation systems are mainly used for monitoring the position of surgical instruments relative to the body of the patient. Present optical navigation systems have a limited applicability (e.g. in neurosurgery), hindered by the high cost and the need of a direct line of sight between the surgical instrument and a video-camera. A micro-inertial measurement unit (IMU) attached to surgical tools or bones can track their position, and improve the global performance. Increased complexity surgical applications will become possible, e.g. bone repositioning in case of facial fractures and osteotomies of craniofacial segments. Several innovative techniques are envisaged, in order to increase the resolution: parametric amplification of mechanical motion, operation in a controlled regime on the stability border, and the use of modern sensing architectures (displacement sensing by optical interferometry or displacement to frequency conversion techniques). The expected performance improvements will widen the application field of computer-assisted surgery (CAS) systems, and complement existing research developments in Canada, focused on other CAS subsystems. In particular, the increased resolution will allow better synchronization with 3D maps of the human body, for automatic or assisted guidance of the tip of surgery instrument inside the patient. Future research will expand the application of these IMUs to medical robotics and intelligent surgery tools. An increased functionality will target active position correction, or cancellation of undesired motion components (e.g. hand-tremor cancellation). This approach will require a more adaptive sensing scheme, with real-time reconfigurable transfer functions.
Programme
Discovery Grants Program - Individual
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
327738-2006
Name nom
Cretu, Edmond
Department département
Electrical and Computer Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2007
Competition year année de concours
2006
Award amount
17000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
334
Committee name en
Commun.,Computers & Components
Committee name fr
Communic.,ordin. et composants
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
2518
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Instrumentation and measurements
Research subject fr
Instrumentation et mesures
Partie
2
Nb partie
5
Application title
SYMBIOM (Synergic inertial microsystems for bio-medical applications)
Keyword
NA
Application summary
The present research program is related to the development of an inertial sensor cluster for navigated surgery, complemented by other intelligent surgery tools. Medical navigation systems are mainly used for monitoring the position of surgical instruments relative to the body of the patient. Present optical navigation systems have a limited applicability (e.g. in neurosurgery), hindered by the high cost and the need of a direct line of sight between the surgical instrument and a video-camera. A micro-inertial measurement unit (IMU) attached to surgical tools or bones can track their position, and improve the global performance. Increased complexity surgical applications will become possible, e.g. bone repositioning in case of facial fractures and osteotomies of craniofacial segments. Several innovative techniques are envisaged, in order to increase the resolution: parametric amplification of mechanical motion, operation in a controlled regime on the stability border, and the use of modern sensing architectures (displacement sensing by optical interferometry or displacement to frequency conversion techniques). The expected performance improvements will widen the application field of computer-assisted surgery (CAS) systems, and complement existing research developments in Canada, focused on other CAS subsystems. In particular, the increased resolution will allow better synchronization with 3D maps of the human body, for automatic or assisted guidance of the tip of surgery instrument inside the patient. Future research will expand the application of these IMUs to medical robotics and intelligent surgery tools. An increased functionality will target active position correction, or cancellation of undesired motion components (e.g. hand-tremor cancellation). This approach will require a more adaptive sensing scheme, with real-time reconfigurable transfer functions.