Grant: Discovery Grants Program - Individual
McGill University
$32,720.00
Development of new methods for the characterization of bio and nanomaterials
EF 2009-10
Résumé
Characterization of the microstructure of materials with a spatial resolution of the order of 1 nm is normally performed using field emission transmission electron microscopy (FE-TEM). This characterization includes quantitative chemical analysis using x-ray microanalysis, the determination of the crystalline structure with electron diffraction and the nature of the atomic bonds using electron energy loss spectroscopy (EELS). FE-TEM requires specimens that must be transparent to the electron beam. Preparing thin foils for FE-TEM observation can be a long and tedious process. However, since it was reported that Fast Secondary Electrons (FSE) can degrade the resolution of X-Ray microanalysis in FE-TEM for the quantification of light elements, the ultimate resolution of this technique is still an issue. Auger electrons were reported recently to have potentially the same effect. Since the mid 1990's, the Field Emission Scanning Electron Microscope (FE-SEM) are available on the market. Low voltage FE-SEM has an image resolution of 2 nm. Since specimen preparation is easier in FE-SEM than in FE-TEM, this explains the increasing popularity of low voltage FE-SEM. Also, transparent thin films for FE-TEM observations have an observable area of 0.25 where polished specimens inserted in the FE-SEM have area of the order of 1cm2. Therefore the area observable in the FE-SEM is 400,000,000 greater than in the TEM, leading to vastly superior statistical information about the microstructure of a given material. However, FE-TEM can determine the microstructure of nanomaterials in three dimension using electron tomography and software development is needed to improve its spatial resolution. This project will develop the scientific software that will allow FE-SEM to perform chemical quantitative x-ray analysis of heterogeneous materials, to determine their crystalline structure by simulating electron backscattered diffraction patterns and to develop a new x-ray detector for soft x-ray spectroscopy. The effect of FSE and Auger electrons on x-ray microanalysis and a new tomography method will also be developed for the FE-TEM.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
121420-2008
Name nom
Gauvin, Raynald
Department département
Mining & Materials Engineering.
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2009
Competition year année de concours
2008
Award amount
32720
Program id
RGPIN
Program nane en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
4
Committee name en
Chem. & Metallurgical Eng.
Committee name fr
Génies chimique et métal.
Area of application code
1208
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Materials sciences
Area of application fr
Sciences des matériaux
Research subject code
2000
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials science and technology
Research subject fr
Science et technologie des matériaux
Partie
2
Nb partie
5
Application title
Development of new methods for the characterization of bio and nanomaterials
Keyword
NA
Application summary
Characterization of the microstructure of materials with a spatial resolution of the order of 1 nm is normally performed using field emission transmission electron microscopy (FE-TEM). This characterization includes quantitative chemical analysis using x-ray microanalysis, the determination of the crystalline structure with electron diffraction and the nature of the atomic bonds using electron energy loss spectroscopy (EELS). FE-TEM requires specimens that must be transparent to the electron beam. Preparing thin foils for FE-TEM observation can be a long and tedious process. However, since it was reported that Fast Secondary Electrons (FSE) can degrade the resolution of X-Ray microanalysis in FE-TEM for the quantification of light elements, the ultimate resolution of this technique is still an issue. Auger electrons were reported recently to have potentially the same effect. Since the mid 1990's, the Field Emission Scanning Electron Microscope (FE-SEM) are available on the market. Low voltage FE-SEM has an image resolution of 2 nm. Since specimen preparation is easier in FE-SEM than in FE-TEM, this explains the increasing popularity of low voltage FE-SEM. Also, transparent thin films for FE-TEM observations have an observable area of 0.25 where polished specimens inserted in the FE-SEM have area of the order of 1cm2. Therefore the area observable in the FE-SEM is 400,000,000 greater than in the TEM, leading to vastly superior statistical information about the microstructure of a given material. However, FE-TEM can determine the microstructure of nanomaterials in three dimension using electron tomography and software development is needed to improve its spatial resolution. This project will develop the scientific software that will allow FE-SEM to perform chemical quantitative x-ray analysis of heterogeneous materials, to determine their crystalline structure by simulating electron backscattered diffraction patterns and to develop a new x-ray detector for soft x-ray spectroscopy. The effect of FSE and Auger electrons on x-ray microanalysis and a new tomography method will also be developed for the FE-TEM.