Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Alliance Grants

Université de Sherbrooke

$131,843.00

A Distributed Neural Recorder/Stimulator for Epilepsy Monitoring

EF 2022-23

Résumé
The potential of neurostimulation to improve quality of life is now well established with examples such as Pacemakers (cardiac arrhythmia), cochlear implants (deafness), deep brain stimulators (Parkinson's treatment) and chronic pain. The global medical neuromodulation market is set to reach $10B by 2024.Epilepsy, characterized by abnormal and excessive brain activity which can lead to violent seizures, affects between 0.5-1% of the population (2.5 M people in United States, ~225k in Canada). As much as 30% of epilepsy patients suffer from intractable drug-resistant epilepsy and can benefit from neurostimulation. Recent research demonstrated seizure forecasting within 24 hours of occurrence, giving the opportunity for seizure mitigative measures and adjustment of activities. However, long-term neural recording/stimulation at multiple cortical targets is still challenging. Among the most challenging aspects of such an implantable device is the acquisition and transmission of data simultaneously from thousands of electrodes distributed at different cortical sites within a practical and clinically safe power budget. This project seeks to develop an application specific integrated circuit (ASIC) targeting epilepsy that will enable neurorecording/stimulation devices with single-neuron resolution, on-chip spike characterization (amplitude and shape) and stimulus pulse shaping, while wirelessly transmitting the compressed data using an algebraic coding scheme. The target implant for this device comprises four ASICS, implanted in the brain at cortical sites suitable for seizure prediction. These ASICs are wired to a central wireless communication hub that transmits the compressed information to an external computer worn by the patient. Unlike other epilepsy recorders limited to few tens of electrodes distributed on an area of few mm2, each integrated circuit is <1 mm2, and will simultaneously records spikes from 1600 channels at a 20 µm pitch. In collaboration with our commercial partners we are creating the first synchronized and distributed 6400-electrode neurorecorder/stimulator system suitable for safe, life-long implantation.This project is conducted in collaboration with Gezell (Gatineau, Canada), the University of Melbourne (Australia) and their industrial partner Carbon Cybernetics Inc. (Melbourne, Australia), who are pioneering very high resolution, 100% biocompatible electrode technology, ultrananocrystalline diamond enclosures and epilepsy prediction algorithms. This partnership perfectly complements our teams composed of the Université de Sherbrooke (Sherbrooke, Canada) and Gezell inc. (Gatineau, Canada) with expertise in microelectronics and product development.
Programme
Alliance Grants
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
557252-2020
Name nom
Fontaine, Réjean RJG
Department département
Génie électrique et génie informatique
Organization id
68
Institution établissement
Université de Sherbrooke
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2022
Competition year année de concours
2020
Award amount
131843
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
2518
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Instrumentation and measurements
Research subject fr
Instrumentation et mesures
Installment
inst:3
Partie
1
Nb partie
3
Application title
A Distributed Neural Recorder/Stimulator for Epilepsy Monitoring
Application summary
The potential of neurostimulation to improve quality of life is now well established with examples such as Pacemakers (cardiac arrhythmia), cochlear implants (deafness), deep brain stimulators (Parkinson's treatment) and chronic pain. The global medical neuromodulation market is set to reach $10B by 2024.Epilepsy, characterized by abnormal and excessive brain activity which can lead to violent seizures, affects between 0.5-1% of the population (2.5 M people in United States, ~225k in Canada). As much as 30% of epilepsy patients suffer from intractable drug-resistant epilepsy and can benefit from neurostimulation. Recent research demonstrated seizure forecasting within 24 hours of occurrence, giving the opportunity for seizure mitigative measures and adjustment of activities. However, long-term neural recording/stimulation at multiple cortical targets is still challenging. Among the most challenging aspects of such an implantable device is the acquisition and transmission of data simultaneously from thousands of electrodes distributed at different cortical sites within a practical and clinically safe power budget. This project seeks to develop an application specific integrated circuit (ASIC) targeting epilepsy that will enable neurorecording/stimulation devices with single-neuron resolution, on-chip spike characterization (amplitude and shape) and stimulus pulse shaping, while wirelessly transmitting the compressed data using an algebraic coding scheme. The target implant for this device comprises four ASICS, implanted in the brain at cortical sites suitable for seizure prediction. These ASICs are wired to a central wireless communication hub that transmits the compressed information to an external computer worn by the patient. Unlike other epilepsy recorders limited to few tens of electrodes distributed on an area of few mm2, each integrated circuit is <1 mm2, and will simultaneously records spikes from 1600 channels at a 20 µm pitch. In collaboration with our commercial partners we are creating the first synchronized and distributed 6400-electrode neurorecorder/stimulator system suitable for safe, life-long implantation.This project is conducted in collaboration with Gezell (Gatineau, Canada), the University of Melbourne (Australia) and their industrial partner Carbon Cybernetics Inc. (Melbourne, Australia), who are pioneering very high resolution, 100% biocompatible electrode technology, ultrananocrystalline diamond enclosures and epilepsy prediction algorithms. This partnership perfectly complements our teams composed of the Université de Sherbrooke (Sherbrooke, Canada) and Gezell inc. (Gatineau, Canada) with expertise in microelectronics and product development.
Université de Sherbrooke - $131,843 Grant (2022-23) | Canada Spends