Grant: Discovery Grants Program - Individual
University of New Brunswick
$38,000.00
Future magnetic resonance measurements of transport phenomena
EF 2024-25
Résumé
Measurements of fluid flow are essential in a huge variety of science and engineering applications, from hydroelectric dams and windfarms to water quality assessments and food processing controls. Some fluid flows are more difficult to measure than others. In particular, where the flow contains a mixtures of fluids (like oil and water) or is optically opaque or very delicate (like a foam) then conventional methods for measuring the flow can fail.
We are developing new and improved apparatus and techniques for measuring fluid flow using magnetic resonance. By passing the fluid through a gradient of magnetic field and using a sensor operating at radio frequencies to interrogate the fluid, we can measure the distribution of fluid velocities in simple and complicated geometries and can deduce information about fluid viscosity or the turbulence of the flow. Our new methods will offer new insight into how turbulent flows are structured and how they develop. We will construct new apparatus for the monitoring of turbulence, which is important because "turbulence is responsible for the vast majority of human energy consumption" (Holmes, Lumley, Berkooz).
The physics principles involved in our measurements are the same as those used in clinical magnetic resonance imaging (MRI) and have all the same advantages: magnetic resonance methods can look inside optically opaque materials, but without inserting any kind of probe or disturbing the fluid in any way. We are developing methods for measuring both the gas and liquid flows in delicate foams, which have important applications in foods, concretes, mining, enhanced oil recovery and water remediation. The cutting-edge facilities at the UNB MRI Centre enable us to develop sophisticated measurements at the highest sensitivities and with greatest flexibility, even including the rotation of fluid flows to different angles in a specially-designed MRI scanner.
In the end, however, the MRI magnets and detectors are expensive and unwieldy. Our research includes adapting our new measurements for use on smaller, cheaper, portable equipment at lower magnetic fields. We have developed expertise in designing and building such compact magnetic resonance equipment and distilling the essential features of more sophisticated measurements onto devices that can be used for process and quality control.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
New Brunswick, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
RGPIN-2023-05880
Name nom
Newling, Benedict
Department département
Physics
Organization id
75
Institution établissement
University of New Brunswick
Province en
New Brunswick
Province fr
Nouveau-Brunswick
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2023
Award amount
38000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1505
Committee name en
Physics
Committee name fr
Physique
Area of application code
1208
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Materials sciences
Area of application fr
Sciences des matériaux
Research subject code
3108
Research subject group en
Physics
Research subject group fr
Physique
Research subject en
Experimental methods and instrumentation
Research subject fr
Méthodes expérimentales et instrumentation
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Future magnetic resonance measurements of transport phenomena
Keywords
magnetic resonance; mri (magnetic resonance imaging); fluid transport; mass transport; flow; diffusion; measurement; turbulence; multi-phase flow
Application summary
Measurements of fluid flow are essential in a huge variety of science and engineering applications, from hydroelectric dams and windfarms to water quality assessments and food processing controls. Some fluid flows are more difficult to measure than others. In particular, where the flow contains a mixtures of fluids (like oil and water) or is optically opaque or very delicate (like a foam) then conventional methods for measuring the flow can fail.
We are developing new and improved apparatus and techniques for measuring fluid flow using magnetic resonance. By passing the fluid through a gradient of magnetic field and using a sensor operating at radio frequencies to interrogate the fluid, we can measure the distribution of fluid velocities in simple and complicated geometries and can deduce information about fluid viscosity or the turbulence of the flow. Our new methods will offer new insight into how turbulent flows are structured and how they develop. We will construct new apparatus for the monitoring of turbulence, which is important because "turbulence is responsible for the vast majority of human energy consumption" (Holmes, Lumley, Berkooz).
The physics principles involved in our measurements are the same as those used in clinical magnetic resonance imaging (MRI) and have all the same advantages: magnetic resonance methods can look inside optically opaque materials, but without inserting any kind of probe or disturbing the fluid in any way. We are developing methods for measuring both the gas and liquid flows in delicate foams, which have important applications in foods, concretes, mining, enhanced oil recovery and water remediation. The cutting-edge facilities at the UNB MRI Centre enable us to develop sophisticated measurements at the highest sensitivities and with greatest flexibility, even including the rotation of fluid flows to different angles in a specially-designed MRI scanner.
In the end, however, the MRI magnets and detectors are expensive and unwieldy. Our research includes adapting our new measurements for use on smaller, cheaper, portable equipment at lower magnetic fields. We have developed expertise in designing and building such compact magnetic resonance equipment and distilling the essential features of more sophisticated measurements onto devices that can be used for process and quality control.