Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Research Tools and Instruments

University of British Columbia

$150,000.00

High-Repetition Rate Laser for Real-Time and 3D Photoacoustic Imaging

EF 2019-20

Résumé
Photoacoustic (PA) imaging is a novel imaging technique that takes the advantages of both optical and ultrasound (US) imaging. Upon absorbing a high energy laser pulse, tissue experiences a rapid and localized heating. The tissue undergoes thermoelastic expansion which generates US waves. The waves propagate towards the tissue surface where they are detected by an US transducer array. PA imaging can image up to a few centimeters into tissue, much deeper than any other optical imaging techniques. Furthermore, PA imaging can detect blood vessels, and quantify blood oxygen saturation and hypoxia, which are highly specific biomarkers of cancer. Thus, PA imaging can augment classical US by adding functional imaging of cancer specific absorption contrasts. Here we propose to develop real-time and 3D photoacoustic tomography (PAT) for detecting prostate and breast cancers. ******Built upon our previous CHRP and CRD grants, a prototype PAT system has been developed for cancer imaging. We have developed an optical fiber catheter to deliver high energy and uniform laser illumination to the prostate through the urethra. An optimum US transducer scanning and detecting geometry has been developed for prostate imaging. Up to 4 cm imaging depth has been demonstrated in ex vivo tissues. For breast cancer imaging, an automated breast ultrasound scanner was used to acquire PAT images. We found that by adding PAT to multi-parametric US can offer a powerful set of metrics for the diagnosis and staging of breast cancer. However, the laser we used before only has 10 Hz repetition rate which is too slow. This has limited the capability of the PAT system to obtain only static images of tissue. For clinical applications, real-time PAT imaging at a speed comparable to US at hundreds of Hertz is needed in order to monitor dynamic changes and overcome motion artifacts. For 3D PAT, hundreds of laser shots are needed in order to acquire PA signals from a 3D volume.******In this application, a laser with fast 100 Hz repetition rate is requested. We propose to develop real-time and 3D PAT for detecting prostate and breast cancers. We will also develop custom PAT/US imagining probes by novel capacitive micromachined ultrasonic transducer (CMUT) arrays that are uniquely large, flexible, and transparent. We will also extend our image analysis approaches from US imaging to PAT. The proposed research program will make major advances in medical imaging by enhancing the capability of US based imaging. By adding the blood absorption and oxygen saturation contrasts from PAT to our multi-parametric US that includes B-mode, elastography, time series, and Doppler, it is expected to greatly enhance the specificity and sensitivity of cancer detection. We will produce and engineer specific techniques of PAT imaging and translate the techniques to clinical applications on prostate and breast cancer imaging. PAT/US imaging will have great potential to improve cancer detection and treatment outcome.
Programme
Research Tools and Instruments
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RTI-2020-00830
Name nom
Tang, Shuo
Department département
Electrical and Computer Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2020
Award amount
150000
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1610
Committee name en
Electrical and Computer Engineering (RTI)
Committee name fr
Génie électrique et infomatique (OIR)
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
High-Repetition Rate Laser for Real-Time and 3D Photoacoustic Imaging
Keyword
NSERC
Application summary
Photoacoustic (PA) imaging is a novel imaging technique that takes the advantages of both optical and ultrasound (US) imaging. Upon absorbing a high energy laser pulse, tissue experiences a rapid and localized heating. The tissue undergoes thermoelastic expansion which generates US waves. The waves propagate towards the tissue surface where they are detected by an US transducer array. PA imaging can image up to a few centimeters into tissue, much deeper than any other optical imaging techniques. Furthermore, PA imaging can detect blood vessels, and quantify blood oxygen saturation and hypoxia, which are highly specific biomarkers of cancer. Thus, PA imaging can augment classical US by adding functional imaging of cancer specific absorption contrasts. Here we propose to develop real-time and 3D photoacoustic tomography (PAT) for detecting prostate and breast cancers. ******Built upon our previous CHRP and CRD grants, a prototype PAT system has been developed for cancer imaging. We have developed an optical fiber catheter to deliver high energy and uniform laser illumination to the prostate through the urethra. An optimum US transducer scanning and detecting geometry has been developed for prostate imaging. Up to 4 cm imaging depth has been demonstrated in ex vivo tissues. For breast cancer imaging, an automated breast ultrasound scanner was used to acquire PAT images. We found that by adding PAT to multi-parametric US can offer a powerful set of metrics for the diagnosis and staging of breast cancer. However, the laser we used before only has 10 Hz repetition rate which is too slow. This has limited the capability of the PAT system to obtain only static images of tissue. For clinical applications, real-time PAT imaging at a speed comparable to US at hundreds of Hertz is needed in order to monitor dynamic changes and overcome motion artifacts. For 3D PAT, hundreds of laser shots are needed in order to acquire PA signals from a 3D volume.******In this application, a laser with fast 100 Hz repetition rate is requested. We propose to develop real-time and 3D PAT for detecting prostate and breast cancers. We will also develop custom PAT/US imagining probes by novel capacitive micromachined ultrasonic transducer (CMUT) arrays that are uniquely large, flexible, and transparent. We will also extend our image analysis approaches from US imaging to PAT. The proposed research program will make major advances in medical imaging by enhancing the capability of US based imaging. By adding the blood absorption and oxygen saturation contrasts from PAT to our multi-parametric US that includes B-mode, elastography, time series, and Doppler, it is expected to greatly enhance the specificity and sensitivity of cancer detection. We will produce and engineer specific techniques of PAT imaging and translate the techniques to clinical applications on prostate and breast cancer imaging. PAT/US imaging will have great potential to improve cancer detection and treatment outcome.