Grant: Research Tools and Instruments
University of Toronto
$135,452.00
Electromagnetic shielding (S-parameters) and electromagnetic parameters measurement system for the frequency domain up to the 50 GHz range
EF 2017-18
Résumé
The consumer electronic and telecommunication sectors continue to grow as the demand and utilization of mobile and smart devices continue to expand. At the same time, there is an increasing urge and demand on electromagnetic interference (EMI) shielding of radio frequency radiation for our society. EMI shielding is required to protect us, our environment, and our workspace from radiation coming from telecommunication equipment and computers. Electrically-conductive polymer composites are one of the most promising materials for this application due to their light weight, resistance to corrosion, flexibility, and processing advantages. To fabricate electrically-conductive polymer composites with tailored properties, precise measurement of EMI shielding effectiveness and electromagnetic parameters (permittivity, permeability, and loss tangent) of materials over ultra-high frequency ranges (radio frequencies) is crucial and highly challenging. We propose the acquisition of a specialized equipment to establish research capacity on the evaluation and analysis of electromagnetic parameters of materials. The equipment will enable precision measurement of the EMI shielding effectiveness and electromagnetic parameters over high frequency ranges of 300 kHz to 50 GHz, at which microwave devices/communications, high-frequency microwave radio relay, microwave remote sensing, wireless LAN, communications satellites, cable and satellite television broadcasting, direct-broadcast satellite (DBS) and radio astronomy operate. At the frequency domain up to the GHz range, the effect of electrical wave become significant and microwave techniques need to be applied where some special and complicated equipment are required. The purchase of requested equipment instrument would be the first in Canada. Canada currently does not have a thin layer dielectric and electromagnetic parameters measurement system over this range of frequency. This equipment along with well-designed dielectric and electromagnetic parameters assessment kit is highly user-friendly and can be used for a broad variety of materials including liquid-like pharmaceutical or biochemical samples, small biological samples (e.g., human skin or tumor tissue samples), solid samples of dielectric materials (e.g. polymer composites), antenna materials, and covers.
Programme
Research Tools and Instruments
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
RTI-2018-00861
Name nom
Park, Chul
Department département
Mechanical and Industrial Engineering - Mechanical and Industrial Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2018
Award amount
135452
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1612
Committee name en
Mechanical Engineering (RTI)
Committee name fr
Génie mecanique (OIR)
Area of application code
500
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Manufacturing processes and products
Area of application fr
Procédés et produits industriels
Research subject code
2002
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials processing
Research subject fr
Transformation des matériaux
Partie
1
Nb partie
1
Application title
Electromagnetic shielding (S-parameters) and electromagnetic parameters measurement system for the frequency domain up to the 50 GHz range
Keyword
NSERC
Application summary
The consumer electronic and telecommunication sectors continue to grow as the demand and utilization of mobile and smart devices continue to expand. At the same time, there is an increasing urge and demand on electromagnetic interference (EMI) shielding of radio frequency radiation for our society. EMI shielding is required to protect us, our environment, and our workspace from radiation coming from telecommunication equipment and computers. Electrically-conductive polymer composites are one of the most promising materials for this application due to their light weight, resistance to corrosion, flexibility, and processing advantages. To fabricate electrically-conductive polymer composites with tailored properties, precise measurement of EMI shielding effectiveness and electromagnetic parameters (permittivity, permeability, and loss tangent) of materials over ultra-high frequency ranges (radio frequencies) is crucial and highly challenging. We propose the acquisition of a specialized equipment to establish research capacity on the evaluation and analysis of electromagnetic parameters of materials. The equipment will enable precision measurement of the EMI shielding effectiveness and electromagnetic parameters over high frequency ranges of 300 kHz to 50 GHz, at which microwave devices/communications, high-frequency microwave radio relay, microwave remote sensing, wireless LAN, communications satellites, cable and satellite television broadcasting, direct-broadcast satellite (DBS) and radio astronomy operate. At the frequency domain up to the GHz range, the effect of electrical wave become significant and microwave techniques need to be applied where some special and complicated equipment are required. The purchase of requested equipment instrument would be the first in Canada. Canada currently does not have a thin layer dielectric and electromagnetic parameters measurement system over this range of frequency. This equipment along with well-designed dielectric and electromagnetic parameters assessment kit is highly user-friendly and can be used for a broad variety of materials including liquid-like pharmaceutical or biochemical samples, small biological samples (e.g., human skin or tumor tissue samples), solid samples of dielectric materials (e.g. polymer composites), antenna materials, and covers.