Grant: Master's Award: Canada Graduate Scholarships
University of Alberta
$17,500.00
High-Field Body Imaging Using Magnetic Resonance Fingerprinting
EF 2014-15
Résumé
The public's best defence against many diseases is early detection and diagnosis. Therefore, a constant goal in diagnostic imaging is the maximization of sensitivity, accuracy, and precision in delineating human disease states. Magnetic resonance imaging (MRI) is a method of diagnostic imaging in the field of medical physics. By applying a magnetic field to a subject, the resultant signal is digitized, and an image of the interior of the subject is created conveniently and painlessly, without the need for invasive surgical procedures.
Challenges are faced in the case of body imaging, for which uncontrollable motion due to breathing or heart-beating result in image distortion. Additionally, high magnetic fields can be used to improve image quality at a cost of increasing effects of non-uniformities, which currently must be compensated for by a time consuming process. Magnetic resonance fingerprinting (MRF) is a novel approach to MRI capable of fast and accurate acquisition of images and has been shown to be insensitive to controlled amounts of patient motion in brain scans, but has not been tested in a realistic high-field body imaging experiment.
My research will address these two issues inherent in high-field body imaging (ie; patient motion and high-field effects). Once I have implemented and verified the MRF process on the human scanner at the University of Alberta, I will design and construct a "dynamic phantom", which is an object placed in the scanner that mimics the biological properties and respiratory/cardiac motion of a human. The images obtained will be compared to a gold-standard method to ensure validity. Upon completion and anticipated success, the ultimate goal of high-field body imaging with human volunteers can be addressed.
Programme
Master's Award: Canada Graduate Scholarships
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
CIHR Funding Decisions Database
Tel que publié
Id
331596
Name
Hough Cameron M
Region
Alberta
Country
Canada
Orgtype
Institution Paid; Research Institution
Prcname2
Special Cases - Awards Programs
Projecttitle
High-Field Body Imaging Using Magnetic Resonance Fingerprinting
Programtype2
Studentship Programs
Orgnameinp2
University of Alberta
Cihramount2
$17,500
Cihrequipment2
$0
Programname2
Master's Award: Canada Graduate Scholarships
Keyworddelim
Artifacts; Diagnostic; Fingerprinting; High-Field; Imaging; Medical; Motion; Mri; Physics; Quantitative
Abstract
The public's best defence against many diseases is early detection and diagnosis. Therefore, a constant goal in diagnostic imaging is the maximization of sensitivity, accuracy, and precision in delineating human disease states. Magnetic resonance imaging (MRI) is a method of diagnostic imaging in the field of medical physics. By applying a magnetic field to a subject, the resultant signal is digitized, and an image of the interior of the subject is created conveniently and painlessly, without the need for invasive surgical procedures.
Challenges are faced in the case of body imaging, for which uncontrollable motion due to breathing or heart-beating result in image distortion. Additionally, high magnetic fields can be used to improve image quality at a cost of increasing effects of non-uniformities, which currently must be compensated for by a time consuming process. Magnetic resonance fingerprinting (MRF) is a novel approach to MRI capable of fast and accurate acquisition of images and has been shown to be insensitive to controlled amounts of patient motion in brain scans, but has not been tested in a realistic high-field body imaging experiment.
My research will address these two issues inherent in high-field body imaging (ie; patient motion and high-field effects). Once I have implemented and verified the MRF process on the human scanner at the University of Alberta, I will design and construct a "dynamic phantom", which is an object placed in the scanner that mimics the biological properties and respiratory/cardiac motion of a human. The images obtained will be compared to a gold-standard method to ensure validity. Upon completion and anticipated success, the ultimate goal of high-field body imaging with human volunteers can be addressed.
Competitiondate
201412
Approvedterm2
1 yr 0 mth
Pinamesdelim
Hough, Cameron M
Approvedterm
1 an 0 mois
Cihrcontribution2
~ $17,500~ $0~