Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Collaborative Research and Development Grants

McGill University

$105,333.00

New Analytical Techniques using Electron Microscopy for Nano-Materials Characterization in the 0.5 - 30 keV Range

EF 2019-20

Résumé
This CRD aims to further develop characterization techniques with the new SU-9000 CFE-SEM acquired by the applicant in 2017 via a CFI as well as on the SU-8230 CFE-SEM. The SU9000 microscope provides advanced STEM capabilities, especially in the form of specific new transmission mode detectors such as bright-field (BF) and dark-field (DF) detectors, an on-axis diffraction camera for convergent beam electron diffraction (CBED) and a unique low voltage electron energy-loss spectrometer (EELS). (1) The EELS technique at low voltages such as 20 and 30 kV will be studied to understand the impact of low beam energy on its operation and its limitations in order to improve its applicability to a wide range of materials. The possibility of reducing further the beam energy below 20 kV will be investigated. (2) Quantitative low voltage CBED applied to several crystalline systems will be studied to propose a convenient procedure to use this new SEM technology as well as apply post-processing techniques to produce useful results with the technique, which are lacking for now. Its limitations will be assessed as well. (3) The new e-Flash high-resolution electron backscatter diffraction (EBSD) camera from Bruker Inc., installed on the SU8230, will also be tested to define its ability in providing CBED in STEM mode in a state-of-the-art SEM. (4) Finally, since the SU9000 is fitted with the new windowless Extreme x-ray detector from Oxford Instruments, very low voltage x-ray microanalysis will be developed in the range of soft x-rays (0 - 1 kV) since this energy range benefits the most of the absence of a protective window on this type of detectors.
Programme
Collaborative Research and Development Grants
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
543484-2019
Name nom
Gauvin, Raynald
Department département
Mining & Materials Engineering.
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2019
Award amount
105333
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1208
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Materials sciences
Area of application fr
Sciences des matériaux
Research subject code
2000
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials science and technology
Research subject fr
Science et technologie des matériaux
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
New Analytical Techniques using Electron Microscopy for Nano-Materials Characterization in the 0.5 - 30 keV Range
Keyword
NSERC
Application summary
This CRD aims to further develop characterization techniques with the new SU-9000 CFE-SEM acquired by the applicant in 2017 via a CFI as well as on the SU-8230 CFE-SEM. The SU9000 microscope provides advanced STEM capabilities, especially in the form of specific new transmission mode detectors such as bright-field (BF) and dark-field (DF) detectors, an on-axis diffraction camera for convergent beam electron diffraction (CBED) and a unique low voltage electron energy-loss spectrometer (EELS). (1) The EELS technique at low voltages such as 20 and 30 kV will be studied to understand the impact of low beam energy on its operation and its limitations in order to improve its applicability to a wide range of materials. The possibility of reducing further the beam energy below 20 kV will be investigated. (2) Quantitative low voltage CBED applied to several crystalline systems will be studied to propose a convenient procedure to use this new SEM technology as well as apply post-processing techniques to produce useful results with the technique, which are lacking for now. Its limitations will be assessed as well. (3) The new e-Flash high-resolution electron backscatter diffraction (EBSD) camera from Bruker Inc., installed on the SU8230, will also be tested to define its ability in providing CBED in STEM mode in a state-of-the-art SEM. (4) Finally, since the SU9000 is fitted with the new windowless Extreme x-ray detector from Oxford Instruments, very low voltage x-ray microanalysis will be developed in the range of soft x-rays (0 - 1 kV) since this energy range benefits the most of the absence of a protective window on this type of detectors.