Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

Lakehead University

$18,000.00

Behaviour of steel-concrete composite columns at elevated temperature

EF 2008-09

Résumé
Interest in fire resistance of structures has increased as a result of the collapse of the two World Trade Centre towers in New York, September 11, 2001.  Our Canadian National Building Code is in the process of becoming an objective-based code containing a mixture of both prescriptive and performance based requirements.  The Code has some provisions for computing the strength reduction of reinforced concrete columns exposed to fire, however, the provisions for the strength reduction of composite steel-concrete columns (steel shapes encased in concrete) exposed to fire are overly simplistic.  The Canadian Standards Association Standard for the Design of Concrete Structures, CSA A23.3, permits design engineers to use the moment magnifier approach to approximate the second-order effects in determining the strength of slender composite columns in frames.  The CSA A23.3, however, does not have provisions for determining column strength that includes for the effects of exposure to fire.      A theoretical model and related computer software, developed by the applicant for previous reinforced concrete and composite steel-concrete column research, will be extended to include for the effects of fire and will be used in the proposed research program. The theoretical model will be compared to physical tests, gathered from published literature, and then be used in a comprehensive parametric study of computer simulated columns to evaluate published design equations and examine the applicability of adopting and/or modifying the moment magnifier approach (CSA A23.3) for computing the strength of reinforced concrete and composite steel-concrete columns subjected to a specified fire duration. The results and recommendations from the research program will be used to prepare draft model clauses and design equations for CSA A23.3 to allow practicing engineers to directly compute the strength of reinforced concrete and composite steel-concrete columns subjected design load(s) and a  fire of prescribed duration.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
261841-2006
Name nom
Tikka, Timo
Department département
Civil Engineering
Organization id
25
Institution établissement
Lakehead University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2008
Competition year année de concours
2006
Award amount
18000
Program id
RGPIN
Program nane en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
6
Committee name en
Civil Engineering
Committee name fr
Génie civil
Area of application code
1206
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Engineering
Area of application fr
Génie
Research subject code
1100
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Structural engineering
Research subject fr
Génie des structures
Partie
3
Nb partie
5
Application title
Behaviour of steel-concrete composite columns at elevated temperature
Keyword
NA
Application summary
Interest in fire resistance of structures has increased as a result of the collapse of the two World Trade Centre towers in New York, September 11, 2001.  Our Canadian National Building Code is in the process of becoming an objective-based code containing a mixture of both prescriptive and performance based requirements.  The Code has some provisions for computing the strength reduction of reinforced concrete columns exposed to fire, however, the provisions for the strength reduction of composite steel-concrete columns (steel shapes encased in concrete) exposed to fire are overly simplistic.  The Canadian Standards Association Standard for the Design of Concrete Structures, CSA A23.3, permits design engineers to use the moment magnifier approach to approximate the second-order effects in determining the strength of slender composite columns in frames.  The CSA A23.3, however, does not have provisions for determining column strength that includes for the effects of exposure to fire.      A theoretical model and related computer software, developed by the applicant for previous reinforced concrete and composite steel-concrete column research, will be extended to include for the effects of fire and will be used in the proposed research program. The theoretical model will be compared to physical tests, gathered from published literature, and then be used in a comprehensive parametric study of computer simulated columns to evaluate published design equations and examine the applicability of adopting and/or modifying the moment magnifier approach (CSA A23.3) for computing the strength of reinforced concrete and composite steel-concrete columns subjected to a specified fire duration. The results and recommendations from the research program will be used to prepare draft model clauses and design equations for CSA A23.3 to allow practicing engineers to directly compute the strength of reinforced concrete and composite steel-concrete columns subjected design load(s) and a  fire of prescribed duration.