Grant: Collaborative Research and Development Grants
Université de Sherbrooke
$44,480.00
Experimental and analytical study of the composite action between Hollowcore precast panels, and standard hot rolled steel beam sections
EF 2021-22
Résumé
Floor construction with precast Hollowcore panels produced by Lafarge Precast Edmonton results in a commonly used rigid floor system. Continuity between the elements is ensured by bent rebars and shear studs. Once all these elements are installed, a structural concrete topping is poured between the reinforced concrete panels and over the entire floor. Engineers currently consider the floor system as a rigid diaphragm. However, the extent of composite action between the rigid diaphragm and the steel beams is not known. Therefore its potential benefit is not taken into account in the current design procedures for the steel structure. Design engineers simply do not consider any composite action between the Hollowcore and the standard hot rolled beam section. The project will allow Lafarge Precast Edmonton and Niche Development corp. to obtain accurate values of parameters needed to eventually calculate the composite action between Hollowcore panels and the steel beams, leading to design equations for bending strength and deflections.
Programme
Collaborative Research and Development Grants
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
543651-2019
Name nom
Roy, Nathalie
Department département
Génie civil
Organization id
68
Institution établissement
Université de Sherbrooke
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2021
Competition year année de concours
2019
Award amount
44480
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Installment
inst:4
Partie
1
Nb partie
4
Application title
Experimental and analytical study of the composite action between Hollowcore precast panels, and standard hot rolled steel beam sections
Keyword
NSERC
Application summary
Floor construction with precast Hollowcore panels produced by Lafarge Precast Edmonton results in a commonly used rigid floor system. Continuity between the elements is ensured by bent rebars and shear studs. Once all these elements are installed, a structural concrete topping is poured between the reinforced concrete panels and over the entire floor. Engineers currently consider the floor system as a rigid diaphragm. However, the extent of composite action between the rigid diaphragm and the steel beams is not known. Therefore its potential benefit is not taken into account in the current design procedures for the steel structure. Design engineers simply do not consider any composite action between the Hollowcore and the standard hot rolled beam section. The project will allow Lafarge Precast Edmonton and Niche Development corp. to obtain accurate values of parameters needed to eventually calculate the composite action between Hollowcore panels and the steel beams, leading to design equations for bending strength and deflections.