Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

University of Waterloo

$24,613.00

Development of Wire Bonding Process and Reliability Evaluation for Gold coated Selenium

EF 2017-18

Résumé
For novel X-ray detectors, amorphous Selenium films are used on top of semiconductor substrates incombination with integrated circuits. Electrical connections to the Selenium layer are needed for operation.Typically, fine wires are used. The requirements for joining of the fine wires to the Selenium include lowtemperature (room temperature ideally), no organic adhesive reacting with Selenium, and small size as thejoints should not obstruct the X-ray images.Microelectronic wire bonding is the main technology to interconnect to integrated circuits. Existing lowtemperature processes of wire bonding are suggested for this project. Wire bonds have 100 % metallic natureand are very small but do not stick to all surfaces. To facilitate wire bonding, the Selenium is coated with a thinGold layer. However, as the Gold coating is thin and the Selenium layer quite soft, wire bonding often resultsin non-sticking failure. The bonds that stick might not be reliable in the long run.The development of a consistent low temperature wire bonding process and its reliability evaluation isproposed in this project to achieve the electrical connection of bonding wire to Gold coated Selenium. Thisprocess will allow the development of miniaturized and high resolution X-ray detectors with sufficient pixels.The project will adopt an improved design-of-experiment methods for the process development combined withreliability methods such as novel current stressing and real time resistance monitoring systems recentlydeveloped at the University of Waterloo. In contrast to other joining methods such as conductive adhesives andsoldering, a successfully developed low temperature wire bonding process to Selenium will maximize theperformance of the X-ray detector. The findings from the process development and reliability evaluation willadd to the knowledge on wire bonding technology in general.
Programme
Engage Grants Program
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
517995-2017
Name nom
Mayer, Michael
Department département
Mechanical Engineering and Mechatronics
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
24613
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
1100
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Health, education and social services
Area of application fr
Santé publique, éducation et services sociaux
Research subject code
2003
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Metallurgy
Research subject fr
Métallurgie
Partie
1
Nb partie
1
Application title
Development of Wire Bonding Process and Reliability Evaluation for Gold coated Selenium
Keyword
NSERC
Application summary
For novel X-ray detectors, amorphous Selenium films are used on top of semiconductor substrates incombination with integrated circuits. Electrical connections to the Selenium layer are needed for operation.Typically, fine wires are used. The requirements for joining of the fine wires to the Selenium include lowtemperature (room temperature ideally), no organic adhesive reacting with Selenium, and small size as thejoints should not obstruct the X-ray images.Microelectronic wire bonding is the main technology to interconnect to integrated circuits. Existing lowtemperature processes of wire bonding are suggested for this project. Wire bonds have 100 % metallic natureand are very small but do not stick to all surfaces. To facilitate wire bonding, the Selenium is coated with a thinGold layer. However, as the Gold coating is thin and the Selenium layer quite soft, wire bonding often resultsin non-sticking failure. The bonds that stick might not be reliable in the long run.The development of a consistent low temperature wire bonding process and its reliability evaluation isproposed in this project to achieve the electrical connection of bonding wire to Gold coated Selenium. Thisprocess will allow the development of miniaturized and high resolution X-ray detectors with sufficient pixels.The project will adopt an improved design-of-experiment methods for the process development combined withreliability methods such as novel current stressing and real time resistance monitoring systems recentlydeveloped at the University of Waterloo. In contrast to other joining methods such as conductive adhesives andsoldering, a successfully developed low temperature wire bonding process to Selenium will maximize theperformance of the X-ray detector. The findings from the process development and reliability evaluation willadd to the knowledge on wire bonding technology in general.