Grant: Collaborative Research and Development Grants

Lakehead University

$45,900.00

Effects of cold temperature and chemical cleaning on performance, membrane fouling and its control in drinking water membrane filtration

EF 2016-17

Résumé
Membrane filtration technology has been widely used for drinking water production all over the world, due to its advantages in better removal of contaminants, high efficiency, small footprint, easy operation, long filtration life, and superior quality of drinking water-free of solids, pathogens, virus and bacteria. However, temperature is a significant factor that affects the performance of membrane filtration. The geographical locations of Canada lead to months of cold temperature each year for many municipalities. The cold temperature has dramatically negative influence on membrane filtration in drinking water production. Each year, thousands of dollars are wasted in each membrane filtration plant in the form of membrane replacements, due to poor operation and membrane cleaning, and membrane structure deterioration in cold temperature. Furthermore, chemical cleanings are routinely used for membrane fouling control. Some of the widely used chemical cleaning agents, such as sodium hypochlorite, have significantly negative impact on membrane structure and thus cause membrane aging and reduce membrane lifespan. Thus, finding replacements for these cleaning agents are highly desirable. The proposed study will develop an improved fundamental understanding of the effect of cold temperature and chemical cleaning on membrane performance, fouling and its control, and membrane structure by conducting bench-, pilot-, and full-scale studies. New operating and membrane cleaning strategies will be developed to optimize the performance of drinking water membrane filtration plants in cold regions in Canada. The findings from this study will help drinking water membrane filtration plants to maximize productivity, minimize membrane fouling, reduce chemical usage and operating costs, and extend membrane lifespan.
Programme
Collaborative Research and Development Grants
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
476874-2014
Name nom
Liao, Baoqiang
Department département
Chemical Engineering
Organization id
25
Institution établissement
Lakehead University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2014
Award amount
45900
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
702
Area of application group en
Transportation systems and services
Area of application group fr
Services et systèmes de transport
Area of application en
Water
Area of application fr
Maritime
Research subject code
1806
Research subject group en
Chemical engineering
Research subject group fr
Génie chimique
Research subject en
Separation processes
Research subject fr
Procédés de séparation
Partie
2
Nb partie
3
Application title
Effects of cold temperature and chemical cleaning on performance, membrane fouling and its control in drinking water membrane filtration
Keyword
NSERC
Application summary
Membrane filtration technology has been widely used for drinking water production all over the world, due to its advantages in better removal of contaminants, high efficiency, small footprint, easy operation, long filtration life, and superior quality of drinking water-free of solids, pathogens, virus and bacteria. However, temperature is a significant factor that affects the performance of membrane filtration. The geographical locations of Canada lead to months of cold temperature each year for many municipalities. The cold temperature has dramatically negative influence on membrane filtration in drinking water production. Each year, thousands of dollars are wasted in each membrane filtration plant in the form of membrane replacements, due to poor operation and membrane cleaning, and membrane structure deterioration in cold temperature. Furthermore, chemical cleanings are routinely used for membrane fouling control. Some of the widely used chemical cleaning agents, such as sodium hypochlorite, have significantly negative impact on membrane structure and thus cause membrane aging and reduce membrane lifespan. Thus, finding replacements for these cleaning agents are highly desirable. The proposed study will develop an improved fundamental understanding of the effect of cold temperature and chemical cleaning on membrane performance, fouling and its control, and membrane structure by conducting bench-, pilot-, and full-scale studies. New operating and membrane cleaning strategies will be developed to optimize the performance of drinking water membrane filtration plants in cold regions in Canada. The findings from this study will help drinking water membrane filtration plants to maximize productivity, minimize membrane fouling, reduce chemical usage and operating costs, and extend membrane lifespan.