Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Collaborative Research and Development Grants

McGill University

$50,435.00

Quantitative X-Ray Microanalysis of Bulk Materials at High Energy (60-400 keV)

EF 2013-14

Résumé
The objective of this project consists of elaborating a simple, reliable and efficient tool for quantitative x-ray microanalysis of bulk specimen in the transmission electron microscope (TEM) for electron energies from 60 to 400 keV. Such tools do not exist presently. In 2009, Bruker introduced the first Silicon Drift Detector (SDD) that can be installed in a TEM that provides, at least, a photon count rate of 500 000 counts/s with energy resolution similar to Si(Li) EDS detectors. The first SDD detector was installed to the Field Emission Scanning Transmission Electron Microscope (FE-STEM) Hitachi HD-2700 of Hydro-Québec Research Center. It is now possible to acquire x-ray spectra of bulk specimen in the TEM for electron energy above 60 keV. However, quantitative x-ray microanalysis of x-ray spectra acquired for electron energies above 60 keV is not possible because the quantitative models that already exist for bulk specimen were developed for electron beam energy below 30 keV, the electron energies used by the electron microprobe and the SEM. This collaborative research grant is to develop, in collaboration with Bruker and Hydro-Québec, a method to perform quantitative x-ray microanalysis of bulk specimen in the 60 - 400 keV range. It is expected that quantitative x-ray microanalysis of bulk specimen in the TEM will lower the detection limit of trace elements. Finally, comparisons will be performed for the analysis of bulk materials between 30 and 200 keV in order to show the advantages and limitations of these energies for quantitative x-ray microanalysis of bulk specimens.
Programme
Collaborative Research and Development Grants
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
428435-2011
Name nom
Gauvin, Raynald
Department département
Mining & Materials Engineering.
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2011
Award amount
50435
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
801
Area of application group en
Information and communication services
Area of application group fr
Services d'information et de télécommunications
Area of application en
Computer software
Area of application fr
Logiciel
Research subject code
2000
Research subject group en
Materials science and technology
Research subject group fr
Science et technologie des matériaux
Research subject en
Materials science and technology
Research subject fr
Science et technologie des matériaux
Partie
2
Nb partie
2
Application title
Quantitative X-Ray Microanalysis of Bulk Materials at High Energy (60-400 keV)
Keyword
NSERC
Application summary
The objective of this project consists of elaborating a simple, reliable and efficient tool for quantitative x-ray microanalysis of bulk specimen in the transmission electron microscope (TEM) for electron energies from 60 to 400 keV. Such tools do not exist presently. In 2009, Bruker introduced the first Silicon Drift Detector (SDD) that can be installed in a TEM that provides, at least, a photon count rate of 500 000 counts/s with energy resolution similar to Si(Li) EDS detectors. The first SDD detector was installed to the Field Emission Scanning Transmission Electron Microscope (FE-STEM) Hitachi HD-2700 of Hydro-Québec Research Center. It is now possible to acquire x-ray spectra of bulk specimen in the TEM for electron energy above 60 keV. However, quantitative x-ray microanalysis of x-ray spectra acquired for electron energies above 60 keV is not possible because the quantitative models that already exist for bulk specimen were developed for electron beam energy below 30 keV, the electron energies used by the electron microprobe and the SEM. This collaborative research grant is to develop, in collaboration with Bruker and Hydro-Québec, a method to perform quantitative x-ray microanalysis of bulk specimen in the 60 - 400 keV range. It is expected that quantitative x-ray microanalysis of bulk specimen in the TEM will lower the detection limit of trace elements. Finally, comparisons will be performed for the analysis of bulk materials between 30 and 200 keV in order to show the advantages and limitations of these energies for quantitative x-ray microanalysis of bulk specimens.