Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Research Tools and Instruments - Category 1 (<$150,000)

Dalhousie University

$150,000.00

A real-time electronic beamformer for high-resolution ultrasound imaging of the Cochlea

EF 2009-10

Résumé
Low-frequency (< 20 MHz) ultrasound (LFUS) is one of the most common imaging modalities in diagnostic medicine, primarily because it is safe, reliable, and real-time. In contrast, high-frequency (>20MHz) ultrasound (HFUS) imaging is a relatively new technique, with an order of magnitude better image resolution compared to low-frequency systems. Despite the improved resolution, HFUS systems are not routinely used in clinical practice. The main barrier preventing their adoption is that until recently, these systems were based on single-element geometrically focused transducers that produced images with a limited depth-of-field and slow frame-rate. In LFUS systems, drastic improvements in both frame-rate and depth-of-field have been achieved by replacing the single-element transducer with a transducer array and an electronic beamformer. This allows electronic focusing at a wide range of depths within the tissue and increased frame-rates. Consequently, there has been a great deal of interest in developing array-based systems for HFUS. Unfortunately, fabricating high-frequency arrays and their associated beamformers is extremely difficult. In particular, to produce a tightly collimated ultrasound beam at these very short wavelengths, array elements with microscopic dimensions are required. In addition, the high frequencies require that the digital sampling resolution of the electronic beamformer and speed of parallel signal processing be greatly increased. In 2009, the world's first commercially available HFUS array-based system was released. The arrays for this system, however, are designed for use in topical applications in which relatively large apertures and packaging are of no concern. We are developing a much smaller HFUS array in an endoscopic form factor, specifically for imaging sub-surface structures of the ear via the ear canal. This proposal seeks infrastructure funding for a real-time 50 MHz digital beamformer. This will allow us to generate real-time images using the custom 50 MHz array endoscopes that we are currently developing using our recently established micro-fabrication facility. Real-time imaging capabilities with Doppler velocimetry are essential to furthering our understanding of inner-ear dynamics.
Programme
Research Tools and Instruments - Category 1 (<$150,000)
Bénéficiaire
Emplacement
Nova Scotia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
390516-2010
Name nom
Brown, Jeremy
Department département
Biomedical Engineering, School of
Organization id
79
Institution établissement
Dalhousie University
Province en
Nova Scotia
Province fr
Nouvelle-Écosse
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2009
Competition year année de concours
2010
Award amount
150000
Program id
EQPEQ
Program nane en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
1
Nb partie
1
Application title
A real-time electronic beamformer for high-resolution ultrasound imaging of the Cochlea
Keyword
NA
Application summary
Low-frequency (< 20 MHz) ultrasound (LFUS) is one of the most common imaging modalities in diagnostic medicine, primarily because it is safe, reliable, and real-time. In contrast, high-frequency (>20MHz) ultrasound (HFUS) imaging is a relatively new technique, with an order of magnitude better image resolution compared to low-frequency systems. Despite the improved resolution, HFUS systems are not routinely used in clinical practice. The main barrier preventing their adoption is that until recently, these systems were based on single-element geometrically focused transducers that produced images with a limited depth-of-field and slow frame-rate. In LFUS systems, drastic improvements in both frame-rate and depth-of-field have been achieved by replacing the single-element transducer with a transducer array and an electronic beamformer. This allows electronic focusing at a wide range of depths within the tissue and increased frame-rates. Consequently, there has been a great deal of interest in developing array-based systems for HFUS. Unfortunately, fabricating high-frequency arrays and their associated beamformers is extremely difficult. In particular, to produce a tightly collimated ultrasound beam at these very short wavelengths, array elements with microscopic dimensions are required. In addition, the high frequencies require that the digital sampling resolution of the electronic beamformer and speed of parallel signal processing be greatly increased. In 2009, the world's first commercially available HFUS array-based system was released. The arrays for this system, however, are designed for use in topical applications in which relatively large apertures and packaging are of no concern. We are developing a much smaller HFUS array in an endoscopic form factor, specifically for imaging sub-surface structures of the ear via the ear canal. This proposal seeks infrastructure funding for a real-time 50 MHz digital beamformer. This will allow us to generate real-time images using the custom 50 MHz array endoscopes that we are currently developing using our recently established micro-fabrication facility. Real-time imaging capabilities with Doppler velocimetry are essential to furthering our understanding of inner-ear dynamics.