Grant: Engage Grants Program
University of British Columbia
$25,000.00
Molecular spectroscopy nano-ring detector project
EF 2012-13
Résumé
The project is a new collaborative relationship between Cavitid Inc., a research and development company in
Edmonton Alberta, founded in 2006, whose principal area of research is in the enhancement of electromagnetic
sensors through the use of a patent pending technology, and the University of British Columbia's silicon
photonics researchers. The aim of the relationship is to advance the current implementation of a microwave
ultra-high Q resonator circuit into a photonic-based nano-scale miniaturized resonator that uses commercial
1.55 microns lasers instead of microwave sources. This technology will open the door to a large number of
applications whereby the sensitivity of the device is up to a thousand times more sensitive than previously
achieved. The application will be detecting acetone molecules from the breath of potential and current diabetes
patients. The sensors produced through this molecular spectroscopy sensor and future work will be the primary
vehicle to obtaining clinically relevant results in this area. The devices will be fabricated using electron-beam
lithography.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
445991-2012
Name nom
Chrostowski, Lukas
Department département
Electrical and Computer Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1554
Committee name en
Pacific Internal Decision Committee
Committee name fr
Comité de décision interne pour le Pacifique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2505
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Photon devices
Research subject fr
Dispositifs photoniques
Partie
1
Nb partie
1
Application title
Molecular spectroscopy nano-ring detector project
Keyword
NSERC
Application summary
The project is a new collaborative relationship between Cavitid Inc., a research and development company in
Edmonton Alberta, founded in 2006, whose principal area of research is in the enhancement of electromagnetic
sensors through the use of a patent pending technology, and the University of British Columbia's silicon
photonics researchers. The aim of the relationship is to advance the current implementation of a microwave
ultra-high Q resonator circuit into a photonic-based nano-scale miniaturized resonator that uses commercial
1.55 microns lasers instead of microwave sources. This technology will open the door to a large number of
applications whereby the sensitivity of the device is up to a thousand times more sensitive than previously
achieved. The application will be detecting acetone molecules from the breath of potential and current diabetes
patients. The sensors produced through this molecular spectroscopy sensor and future work will be the primary
vehicle to obtaining clinically relevant results in this area. The devices will be fabricated using electron-beam
lithography.