Grant: Engage Grants Program
Concordia University
$25,000.00
Bearing Health Monitoring and Clogged Spout Detection Using Finite Element Analysis and Advanced Signal Processing Technique
EF 2016-17
Résumé
NOW! Energy Solution (NES) is currently involved in a project to supply the engineering and fabrication oftwo cantilevered articulated booms for ship loading at the Marine Terminal of the McInnis Cement Plant inPort Daniel-Gascons which benefits Canada by operating one of its kind efficient world class low carbonemission cement production facility. The articulated booms are essential to deliver cement from the silos,located on the shore, and load the ships. They include four large custom made bearings and several smallerones. Any failure in the bearings should be detected early enough to have time for ordering a new one andavoiding system shutdown. The second issue, which may cause severe problem for the booms and supportingtowers, is occurrence of the clogged spout, due to mixture of cement and water. The clogged spout situationapplies significant load and moment to different components of the structure, which may result in structural orfatigue failure. This project addresses these two issues and concerns with early detection of clogged spout andhealth monitoring of the custom made bearings used in the articulated boom structures. The bearing fault mayoccur due to wear, foreign debris or crack in the bearing supporting structure, while the clogged spout mayhappen due to unexpected mixture of cement with water, which results cement accumulation in the tip of theboom. These two failures can be catastrophic and can cause countless hours of operation stoppage, potentiallycosting millions of dollars. The present study employs finite element (FE) method to obtain the stressdistribution in different components of the structure under different configurations and loading scenarios. Thestress magnitudes in the articulated boom are also measured by NES using strain gauges attached to thestructure. The FE results and measured data are utilized to develop an ON-OFF controller to shut down thecircuit before clogged spout become critical. The vibration characteristics of the bearings are also captured andanalyzed using advanced signal processing techniques. Hilbert-Huang and wavelet transform techniques will beutilized to develop a reliable method to detect bearing failure, and their performances will be compared.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
503898-2016
Name nom
Sedaghati, Ramin
Department département
Mechanical and Industrial Engineering
Organization id
70
Institution établissement
Concordia University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2016
Competition year année de concours
2016
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
2107
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Modelling, simulation and finite element methods
Research subject fr
Modélisation, simulation et méthodes des éléments finis
Partie
1
Nb partie
1
Application title
Bearing Health Monitoring and Clogged Spout Detection Using Finite Element Analysis and Advanced Signal Processing Technique
Keyword
NSERC
Application summary
NOW! Energy Solution (NES) is currently involved in a project to supply the engineering and fabrication oftwo cantilevered articulated booms for ship loading at the Marine Terminal of the McInnis Cement Plant inPort Daniel-Gascons which benefits Canada by operating one of its kind efficient world class low carbonemission cement production facility. The articulated booms are essential to deliver cement from the silos,located on the shore, and load the ships. They include four large custom made bearings and several smallerones. Any failure in the bearings should be detected early enough to have time for ordering a new one andavoiding system shutdown. The second issue, which may cause severe problem for the booms and supportingtowers, is occurrence of the clogged spout, due to mixture of cement and water. The clogged spout situationapplies significant load and moment to different components of the structure, which may result in structural orfatigue failure. This project addresses these two issues and concerns with early detection of clogged spout andhealth monitoring of the custom made bearings used in the articulated boom structures. The bearing fault mayoccur due to wear, foreign debris or crack in the bearing supporting structure, while the clogged spout mayhappen due to unexpected mixture of cement with water, which results cement accumulation in the tip of theboom. These two failures can be catastrophic and can cause countless hours of operation stoppage, potentiallycosting millions of dollars. The present study employs finite element (FE) method to obtain the stressdistribution in different components of the structure under different configurations and loading scenarios. Thestress magnitudes in the articulated boom are also measured by NES using strain gauges attached to thestructure. The FE results and measured data are utilized to develop an ON-OFF controller to shut down thecircuit before clogged spout become critical. The vibration characteristics of the bearings are also captured andanalyzed using advanced signal processing techniques. Hilbert-Huang and wavelet transform techniques will beutilized to develop a reliable method to detect bearing failure, and their performances will be compared.