Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Collaborative Health Research Projects

McGill University

$179,220.00

Bio-integrated fully implantable peripheral nerve electrode for functional upper limb prostheses

EF 2017-18

Résumé
The development of electrodes that can be implanted into nerves and used to communicate with robotic limbs is an excitingadvance for patients with upper limb amputations. In two recent experimental cases, electrodes were implanted into humannerves, enabling the recipients to remotely control a robotic limb, manipulate a wheelchair and receive some sensoryfeedback from handling objects with a robotic hand. However, significant drawbacks remain with these systems which mustbe resolved before the technology can be used in the general population. These include the gradual encasing of electrodesin scar tissue due to foreign-body reaction, diminishing the ability of the electrode to communicate with the nervous systemover time. More significantly, the two systems that have been successfully implanted to date require the use of wire leadsthat connect from the implanted electrode through the skin to the signal amplifier/transmitter which is located outside thebody. This presents a significant risk for infection or disconnection of the leads from the electrodes. Our group hasdeveloped techniques to coat synthetic surfaces with compounds that act to induce nearby nerve cells to form functionalsynapses onto the camouflaged synthetic surface. Synapses are the specialized junctions made between nerve cells thatallow them to communicate with one another in a network. By inducing the formation of synapses onto the surface of theimplanted electrodes, the formation of scar tissue between the nerve cell and the electrode will be diminished. Our industrialpartner, NxtSens Microsystems, has developed implantable microchips with the ability to capture, amplify and wirelesslytransmit electrical signals from electrodes connected to the nervous system which can then connect remotely to a prostheticlimb. Our objective is to develop a highly stable, fully implantable electrode-transmitter device that can be used for long-termneural-technology communication.
Programme
Collaborative Health Research Projects
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
493633-2016
Name nom
Kennedy, Timothy
Department département
Neurology and Neurosurgery
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2016
Award amount
179220
Program id
CHRPJ
Program name en
Collaborative Health Research Projects
Program name fr
Projets de recherche concertée sur la santé
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
360
Committee name en
Collaborative Health Research Projects Selection Panel
Committee name fr
Comité de sélection de projets de recherche concertée sur la santé
Area of application code
9999
Area of application group en
Not available
Area of application group fr
Non disponible
Area of application en
Not available
Area of application fr
Non disponible
Research subject code
9999
Research subject group en
Not available
Research subject group fr
Non disponible
Research subject en
Not available
Research subject fr
Non disponible
Partie
2 & 3
Nb partie
3
Application title
Bio-integrated fully implantable peripheral nerve electrode for functional upper limb prostheses
Keyword
NSERC
Application summary
The development of electrodes that can be implanted into nerves and used to communicate with robotic limbs is an excitingadvance for patients with upper limb amputations. In two recent experimental cases, electrodes were implanted into humannerves, enabling the recipients to remotely control a robotic limb, manipulate a wheelchair and receive some sensoryfeedback from handling objects with a robotic hand. However, significant drawbacks remain with these systems which mustbe resolved before the technology can be used in the general population. These include the gradual encasing of electrodesin scar tissue due to foreign-body reaction, diminishing the ability of the electrode to communicate with the nervous systemover time. More significantly, the two systems that have been successfully implanted to date require the use of wire leadsthat connect from the implanted electrode through the skin to the signal amplifier/transmitter which is located outside thebody. This presents a significant risk for infection or disconnection of the leads from the electrodes. Our group hasdeveloped techniques to coat synthetic surfaces with compounds that act to induce nearby nerve cells to form functionalsynapses onto the camouflaged synthetic surface. Synapses are the specialized junctions made between nerve cells thatallow them to communicate with one another in a network. By inducing the formation of synapses onto the surface of theimplanted electrodes, the formation of scar tissue between the nerve cell and the electrode will be diminished. Our industrialpartner, NxtSens Microsystems, has developed implantable microchips with the ability to capture, amplify and wirelesslytransmit electrical signals from electrodes connected to the nervous system which can then connect remotely to a prostheticlimb. Our objective is to develop a highly stable, fully implantable electrode-transmitter device that can be used for long-termneural-technology communication.