Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Collaborative Health Research Projects

École Polytechnique de Montréal

$65,215.00

Reduction of metal artifacts in X-ray computed tomography. Application to vascular imaging in the presence of stents

EF 2007-08

Résumé
Blood vessel occlusion - due to atherosclerosis or other causes - is an important health problem for which stent placement is a widespread treatment procedure. Follow-up of the patients is required in order to evaluate and detect in-stent restenosis caused by thrombus formation or neointimal hyperplasia. Therefore, there is a strong need for precise and nearly noninvasive techniques for assessing the lumen cross-section inside the stent. Unfortunately, most commonly available imaging modalities, including X-ray computed tomography (CT) and magnetic resonance imaging, yield poor  and unreliable results due to the strong metal artifacts induced by the stent. The goal of the project is to develop and validate X-ray CT image reconstruction techniques that present significant reduction of metal artifacts, with applications to vascular imaging and restenosis assessment after stent placement. The project will be carried out in four stages: - Enhancement of realistic vascular phantoms, so as to offer the possibility of inserting various types of stents and of modeling various degrees of restenosis. - Development and validation of an initial 2D X-ray CT, that will be based on an accurate model of the phenomena causing X-ray artifacts, and that will be able to reconstruct images of realistic size (512x512 pixels) reasonably fast. - 3D extension and validation of the method by developing efficient numerical techniques and by taking advantage of the special structure of the reconstruction problem. - Clinical feasibility study, that will constitute the initial stage of the dissemination and translation of the methods developed in-the course of the project.
Programme
Collaborative Health Research Projects
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
323572-2006
Name nom
Goussard, Yves
Department département
Génie électrique
Organization id
64
Institution établissement
École Polytechnique de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2007
Competition year année de concours
2006
Award amount
65215
Program id
CHRPJ
Program name en
Collaborative Health Research Projects
Program name fr
Projets de recherche concertée sur la santé
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
360
Committee name en
Collaborative Health Research Projects Selection Panel
Committee name fr
Comité de sélection de projets de recherche concertée sur la santé
Area of application code
1101
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Human health (including medically-related psychological research)
Area of application fr
Santé publique (y compris recherche psychologique liée à la médecine)
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
2
Nb partie
3
Application title
Reduction of metal artifacts in X-ray computed tomography. Application to vascular imaging in the presence of stents
Keyword
NA
Application summary
Blood vessel occlusion - due to atherosclerosis or other causes - is an important health problem for which stent placement is a widespread treatment procedure. Follow-up of the patients is required in order to evaluate and detect in-stent restenosis caused by thrombus formation or neointimal hyperplasia. Therefore, there is a strong need for precise and nearly noninvasive techniques for assessing the lumen cross-section inside the stent. Unfortunately, most commonly available imaging modalities, including X-ray computed tomography (CT) and magnetic resonance imaging, yield poor  and unreliable results due to the strong metal artifacts induced by the stent. The goal of the project is to develop and validate X-ray CT image reconstruction techniques that present significant reduction of metal artifacts, with applications to vascular imaging and restenosis assessment after stent placement. The project will be carried out in four stages: - Enhancement of realistic vascular phantoms, so as to offer the possibility of inserting various types of stents and of modeling various degrees of restenosis. - Development and validation of an initial 2D X-ray CT, that will be based on an accurate model of the phenomena causing X-ray artifacts, and that will be able to reconstruct images of realistic size (512x512 pixels) reasonably fast. - 3D extension and validation of the method by developing efficient numerical techniques and by taking advantage of the special structure of the reconstruction problem. - Clinical feasibility study, that will constitute the initial stage of the dissemination and translation of the methods developed in-the course of the project.