Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Research Tools and Instruments

University of Calgary

$121,330.00

Small Animal Muscle Dynamometry System

EF 2019-20

Résumé
Request: We are requesting $ 121,330 for the purchase of a world-unique small animal muscle testing system, that will allow for the simultaneous and instantaneous measurement of muscle force, fascicle length, and changes in individual sarcomere lengths in skeletal muscles of small animals (mice, frogs, rats), while controlling all activation parameters. The system is a combination of multi-photon and second harmonic generation microscopy and a mechanical tester for small skeletal muscles. We already have a cutting-edge multi-photon excitation microscope powered by two femto-second pulsed lasers that allow for second harmonic generation microscopy. This system was purchased with a recent Canada Foundation for Innovation grant for approximately $ CDN 1.2 million. The microscope system allows for deep tissue penetration and accurate identification of the anisotropic bands (A-bands or myosin filament region) of individual sarcomeres, thus allowing for instantaneous measurements of individual sarcomere lengths, sarcomere velocities and sarcomere length non-uniformities during dynamic muscle contractions. With this RTI application, we would like to expand this system to include a mechanical testing system for skeletal muscles from small animals for full description of the mechanics of muscle contraction while measuring simultaneously the sarcomere dynamics. Such a system cannot be purchased commercially, and we propose to buy the required system components and build the system in house. The uniqueness of the system lies in the fact that we will be able to visualize single sarcomeres along strings of serial sarcomeres in an entire muscle during contraction, and quantify instantaneous sarcomere lengths, sarcomere length non-uniformities, and dynamic interactions of individual sarcomeres in an entire muscle, thus providing relevant and currently inaccessible information to muscle physiologists and biomechanists. ***Once finalized, this equipment system will allow us to address some fundamental questions in muscle mechanics, including the relationship between sarcomere length non-uniformities and basic muscle properties, such as the isometric force-length relationship, residual force enhancement following eccentric contraction, and instabilities of sarcomere length and force on the descending limb of the force-length relationship. Although some of these ideas have been contemplated for decades, the proposed system will be the first to allow for systematic evaluation of sarcomere lengths non-uniformities and skeletal muscle properties and function.***We have conceived this idea in consultation with local and international colleagues who are eager to collaborate with us, and send us students for specific projects, once this system has been fully implemented, tested and validated. Pilot results using static, steady- state, and passive muscles using second harmonic generation microscopy, have provided encouraging results. **
Programme
Research Tools and Instruments
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RTI-2020-00025
Name nom
Herzog, Walter
Department département
Kinesiology, Faculty of
Organization id
11
Institution établissement
University of Calgary
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2020
Award amount
121330
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1602
Committee name en
Biological Systems and Functions (RTI)
Committee name fr
Systèmes et fonctions biologiques (OIR)
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
Small Animal Muscle Dynamometry System
Keyword
NSERC
Application summary
Request: We are requesting $ 121,330 for the purchase of a world-unique small animal muscle testing system, that will allow for the simultaneous and instantaneous measurement of muscle force, fascicle length, and changes in individual sarcomere lengths in skeletal muscles of small animals (mice, frogs, rats), while controlling all activation parameters. The system is a combination of multi-photon and second harmonic generation microscopy and a mechanical tester for small skeletal muscles. We already have a cutting-edge multi-photon excitation microscope powered by two femto-second pulsed lasers that allow for second harmonic generation microscopy. This system was purchased with a recent Canada Foundation for Innovation grant for approximately $ CDN 1.2 million. The microscope system allows for deep tissue penetration and accurate identification of the anisotropic bands (A-bands or myosin filament region) of individual sarcomeres, thus allowing for instantaneous measurements of individual sarcomere lengths, sarcomere velocities and sarcomere length non-uniformities during dynamic muscle contractions. With this RTI application, we would like to expand this system to include a mechanical testing system for skeletal muscles from small animals for full description of the mechanics of muscle contraction while measuring simultaneously the sarcomere dynamics. Such a system cannot be purchased commercially, and we propose to buy the required system components and build the system in house. The uniqueness of the system lies in the fact that we will be able to visualize single sarcomeres along strings of serial sarcomeres in an entire muscle during contraction, and quantify instantaneous sarcomere lengths, sarcomere length non-uniformities, and dynamic interactions of individual sarcomeres in an entire muscle, thus providing relevant and currently inaccessible information to muscle physiologists and biomechanists. ***Once finalized, this equipment system will allow us to address some fundamental questions in muscle mechanics, including the relationship between sarcomere length non-uniformities and basic muscle properties, such as the isometric force-length relationship, residual force enhancement following eccentric contraction, and instabilities of sarcomere length and force on the descending limb of the force-length relationship. Although some of these ideas have been contemplated for decades, the proposed system will be the first to allow for systematic evaluation of sarcomere lengths non-uniformities and skeletal muscle properties and function.***We have conceived this idea in consultation with local and international colleagues who are eager to collaborate with us, and send us students for specific projects, once this system has been fully implemented, tested and validated. Pilot results using static, steady- state, and passive muscles using second harmonic generation microscopy, have provided encouraging results. **