Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

University of Waterloo

$25,000.00

Microfabrication of calibration samples for laser imaging scanner

EF 2013-14

Résumé
Traditionally, the diagnostic analysis of disease at the cellular level has involved looking at tissue slices through a conventional optical microscope. Since 1999, whole slide imaging (WSI) has experienced a rapid growth, using laser scanning or ""virtual microscopy"" to produce ""digital slides"". These can then be viewed by humans or subjected to automated image analysis. This project will help develop the next generation of WSI technology, which is essential for accurate and unambiguous disease diagnostics. The supporting company, Huron Technologies (Waterloo, ON), is a world leader in this field. Its key product, TISSUEscope, is the most versatile digital pathology platform on the market, providing speed, flexibility and unmatched image quality (down to 0.25µm resolution).As with any type of microscopy, calibration of Huron's TISSUEscope is essential for imaging accuracy and quantitative analysis. In 2013 Huron designed a new higher resolution laser scan lens that will be manufactured in 2014. This will require advanced calibration standards beyond those commercially available. Therefore, the objective of the project is for Waterloo's team to develop calibration standard samples. These samples will be fabricated inside a cleanroom environment, using lithography, thin film deposition and etching technology; the same technology is used to manufacture semiconducting chips. For scale up with low cost and high throughput, nanoimprint lithography will be employed. Success will help Huron (and Canada) maintain its leading position by offering a tissue-scope with the highest image resolution in the market. Furthermore, as nanoimprint lithography is a viable commercial production method, Huron has intention to commercialize the calibration standards that are currently unavailable on the market.
Programme
Engage Grants Program
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
461909-2013
Name nom
Cui, Bo
Department département
Electrical & Computer Engineering
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2013
Competition year année de concours
2013
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
2523
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Semiconductor fabrication and packaging
Research subject fr
Fabrication et mise sous enveloppe de semi-conducteurs
Partie
1
Nb partie
1
Application title
Microfabrication of calibration samples for laser imaging scanner
Keyword
NSERC
Application summary
Traditionally, the diagnostic analysis of disease at the cellular level has involved looking at tissue slices through a conventional optical microscope. Since 1999, whole slide imaging (WSI) has experienced a rapid growth, using laser scanning or ""virtual microscopy"" to produce ""digital slides"". These can then be viewed by humans or subjected to automated image analysis. This project will help develop the next generation of WSI technology, which is essential for accurate and unambiguous disease diagnostics. The supporting company, Huron Technologies (Waterloo, ON), is a world leader in this field. Its key product, TISSUEscope, is the most versatile digital pathology platform on the market, providing speed, flexibility and unmatched image quality (down to 0.25µm resolution).As with any type of microscopy, calibration of Huron's TISSUEscope is essential for imaging accuracy and quantitative analysis. In 2013 Huron designed a new higher resolution laser scan lens that will be manufactured in 2014. This will require advanced calibration standards beyond those commercially available. Therefore, the objective of the project is for Waterloo's team to develop calibration standard samples. These samples will be fabricated inside a cleanroom environment, using lithography, thin film deposition and etching technology; the same technology is used to manufacture semiconducting chips. For scale up with low cost and high throughput, nanoimprint lithography will be employed. Success will help Huron (and Canada) maintain its leading position by offering a tissue-scope with the highest image resolution in the market. Furthermore, as nanoimprint lithography is a viable commercial production method, Huron has intention to commercialize the calibration standards that are currently unavailable on the market.