Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Research Tools and Instruments

University of Toronto

$150,000.00

Equipment for biomechanical characterization of organ-on-a-chip devices

EF 2020-21

Résumé
We are requesting two unique and customized micromechanical testers that enable delineation of in situ mechanical properties of organ-on-a-chip devices fabricated on a foot print of a well plate. Such micromechanical testers are not currently available in the region and only basic models are available in Canada. A unique feature of our organ-on-a-chip devices is that polymeric materials serve to both anchor the tissue and sense the force exerted by them, thus enabling continuous functional readouts by visualization of polymer material deflection. Accurate force readouts require calibration for which these micromechanical in situ testers are urgently needed. The requested model can measure forces down to 10nN at a physiological material temperature and a spatial resolution for displacement of 0.1um. Without accurate force readouts, drug testing results are meaningless defying the ultimate purpose of organ-on-a-chip research. The requested micromechanical tester will be customized for this application to enable testing of devices with a foot print of a 96-well plate. Devices in each well will be tested serially without the need to reload the sample. Standard models only allow placement of one material at the time into the testing chamber. Our research progress, ability to innovate on the current organ-on-a-chip device design, ability to publish as well as to commercialize new devices are on hold until the new micromechanical testers are obtained. We are also requesting an SLA 3D printer and a biosafety cabinet to increase the throughput of production of these organ-on-a-chip devices and introduce sterile fabrication capability. The requested equipment will be used by 35 trainees from the co-applicant laboratories (Radisic, Guenther, Simmons and You). Additional 227 trainees from 63PIs will have access to this equipment through the shared facility co-founded by Drs. Guenther and Radisic: Centre for Research and Applications in Fluidic Technologies (CRAFT). Also benefiting from this equipment will be 59 trainees from the NSERC CREATE Training Program in Organ-on-a-Chip Engineering 25% minority, 75% immigrant) enabling training in a diverse environment.
Programme
Research Tools and Instruments
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RTI-2021-00784
Name nom
Radisic, Milica
Department département
IBBME/Chemical Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2020
Competition year année de concours
2021
Award amount
150000
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1611
Committee name en
Materials and Chemical Engineering (RTI)
Committee name fr
Génie chimique et des matériaux (OIR)
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Installment
inst:1-1
Partie
1
Nb partie
1
Application title
Equipment for biomechanical characterization of organ-on-a-chip devices
Keyword
NSERC
Application summary
We are requesting two unique and customized micromechanical testers that enable delineation of in situ mechanical properties of organ-on-a-chip devices fabricated on a foot print of a well plate. Such micromechanical testers are not currently available in the region and only basic models are available in Canada. A unique feature of our organ-on-a-chip devices is that polymeric materials serve to both anchor the tissue and sense the force exerted by them, thus enabling continuous functional readouts by visualization of polymer material deflection. Accurate force readouts require calibration for which these micromechanical in situ testers are urgently needed. The requested model can measure forces down to 10nN at a physiological material temperature and a spatial resolution for displacement of 0.1um. Without accurate force readouts, drug testing results are meaningless defying the ultimate purpose of organ-on-a-chip research. The requested micromechanical tester will be customized for this application to enable testing of devices with a foot print of a 96-well plate. Devices in each well will be tested serially without the need to reload the sample. Standard models only allow placement of one material at the time into the testing chamber. Our research progress, ability to innovate on the current organ-on-a-chip device design, ability to publish as well as to commercialize new devices are on hold until the new micromechanical testers are obtained. We are also requesting an SLA 3D printer and a biosafety cabinet to increase the throughput of production of these organ-on-a-chip devices and introduce sterile fabrication capability. The requested equipment will be used by 35 trainees from the co-applicant laboratories (Radisic, Guenther, Simmons and You). Additional 227 trainees from 63PIs will have access to this equipment through the shared facility co-founded by Drs. Guenther and Radisic: Centre for Research and Applications in Fluidic Technologies (CRAFT). Also benefiting from this equipment will be 59 trainees from the NSERC CREATE Training Program in Organ-on-a-Chip Engineering 25% minority, 75% immigrant) enabling training in a diverse environment.