Data-driven decarbonization of health care buildings

EF 2024-25

Résumé
Heating, ventilation, and air conditioning (HVAC) systems in health care buildings in Canada account for 150 PJ of energy (1.6% of Canada's total energy use) and are responsible for 8 Mt of CO2,eq GHG emissions (1.2% of Canada's total emissions). This project, in partnership with an established Canadian construction services company specialized in sustainable building design, construction, and operation (EllisDon), will develop a data-driven workflow aiming to reduce the energy use and GHG emissions from this understudied building typology by 30%. The workflow will integrate methods for a) the assessment of the design and actual performance gap, b) detection of design, construction, and operation faults, c) automated calibration of building performance simulation (BPS) models, d) BPS-based optimization of the HVAC sequences of operation, e) occupancy-centric control (OCC) algorithms that ensure indoor air quality while eliminating the energy waste due to conditioning of vacant spaces, f) a surrogate model-based software tool for continuous monitoring by the non-engineering facilities management staff. The workflow will be developed by using the BPS models, building management system (BMS) trend data, and controls, architectural, and mechanical design drawings for real health care buildings designed, constructed, and operated by the partner. Implementation by the partner organisation combined with broader dissemination of the outcomes through journal, conference, and magazine articles will generate utility cost savings, increase the productivity of facilities services teams, and contribute to businesses in sustainable building design, construction, and operation. Patients and staff in Canadian health care facilities will also directly benefit through OCC. Wider adoption of the outcomes will contribute to Canada's GHG emission reduction targets. Three graduate students will be trained with advanced skills in controls and automation of HVAC systems, BPS, indoor air quality, and data analytics.
Programme
Alliance Grants
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
590911-2023
Name nom
Gunay, Burak BH
Department département
Civil and Environmental Engineering
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2023
Award amount
25000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Data-driven decarbonization of health care buildings
Keywords
building automation systems; decarbonization; energy performance gap; fault detection and diagnostics; health care facilities; hvac systems; occupant-centric controls; surrogate modelling
Application summary
Heating, ventilation, and air conditioning (HVAC) systems in health care buildings in Canada account for 150 PJ of energy (1.6% of Canada's total energy use) and are responsible for 8 Mt of CO2,eq GHG emissions (1.2% of Canada's total emissions). This project, in partnership with an established Canadian construction services company specialized in sustainable building design, construction, and operation (EllisDon), will develop a data-driven workflow aiming to reduce the energy use and GHG emissions from this understudied building typology by 30%. The workflow will integrate methods for a) the assessment of the design and actual performance gap, b) detection of design, construction, and operation faults, c) automated calibration of building performance simulation (BPS) models, d) BPS-based optimization of the HVAC sequences of operation, e) occupancy-centric control (OCC) algorithms that ensure indoor air quality while eliminating the energy waste due to conditioning of vacant spaces, f) a surrogate model-based software tool for continuous monitoring by the non-engineering facilities management staff. The workflow will be developed by using the BPS models, building management system (BMS) trend data, and controls, architectural, and mechanical design drawings for real health care buildings designed, constructed, and operated by the partner. Implementation by the partner organisation combined with broader dissemination of the outcomes through journal, conference, and magazine articles will generate utility cost savings, increase the productivity of facilities services teams, and contribute to businesses in sustainable building design, construction, and operation. Patients and staff in Canadian health care facilities will also directly benefit through OCC. Wider adoption of the outcomes will contribute to Canada's GHG emission reduction targets. Three graduate students will be trained with advanced skills in controls and automation of HVAC systems, BPS, indoor air quality, and data analytics.