Grant: Collaborative Research and Development Grants
University of Waterloo
$33,939.00
On-line monitoring and diagnosis for preventive maintenance of high and medium voltage circuit breakers
EF 2006-07
Résumé
Circuit breakers primary functions are to interrupt faults and to perform switching operation. These functions are necessary for a safe and reliable operation for medium voltage (MV) and high voltage (HV) substations. In this regard circuit breakers are considered as essential components in MV and HV substations and their reliability affect directly the operation and the reliability of the entire substations. Circuit breakers have to fulfill number of requirements based on their location in the network and their primary functions. To insure that the circuit breaker is operating within these requirements routine maintenance is performed on the breaker. The present trend for scheduled maintenance is relying on Time-Based Maintenance (TBM) and Condition-Based Maintenance (CBM), which are usually based on equipment type, elapsed time, equipment history maintenance, or number of operations. In order to stay competitive in today's market, electric utilities are being pressured to reduce their overhaul and maintenance costs, which represent a significant portion of the overall costs. One way to accomplish this goal is by extending the interval between maintenance cycles, or performing maintenance based on equipment condition rather than time. To achieve this task the TBM and CBM are being directed more towards a Reliability Centered Maintenance (RCM) program which is based on a number of parameters such as substation and breaker criticality to the system, maintenance history and diagnostic technologies to identify problems or indications when maintenance is required. The aim of this study is to develop an On-Line Monitoring Diagnostic Unit (OLMDU) for different classes of circuit breakers. The proposed OLMDU will carry out data acquisition and processing in order to extract the significant features in the data and then it will use artificial intelligence agents to achieve the proper diagnosis. Data compression techniques will be used to store the data for further analysis if needed.
Programme
Collaborative Research and Development Grants
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
321655-2005
Name nom
ElSaadany, Ehab
Department département
Electrical & Computer Engineering
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2006
Competition year année de concours
2005
Award amount
33939
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
513
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Electrical and electronic machinery and equipment (including computer hardware)
Area of application fr
Machinerie et équipement électriques et électroniques (y compris matériel informatique)
Research subject code
2500
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electrical and electronic engineering
Research subject fr
Génie électrique et électronique
Partie
2
Nb partie
2
Application title
On-line monitoring and diagnosis for preventive maintenance of high and medium voltage circuit breakers
Keyword
NA
Application summary
Circuit breakers primary functions are to interrupt faults and to perform switching operation. These functions are necessary for a safe and reliable operation for medium voltage (MV) and high voltage (HV) substations. In this regard circuit breakers are considered as essential components in MV and HV substations and their reliability affect directly the operation and the reliability of the entire substations. Circuit breakers have to fulfill number of requirements based on their location in the network and their primary functions. To insure that the circuit breaker is operating within these requirements routine maintenance is performed on the breaker. The present trend for scheduled maintenance is relying on Time-Based Maintenance (TBM) and Condition-Based Maintenance (CBM), which are usually based on equipment type, elapsed time, equipment history maintenance, or number of operations. In order to stay competitive in today's market, electric utilities are being pressured to reduce their overhaul and maintenance costs, which represent a significant portion of the overall costs. One way to accomplish this goal is by extending the interval between maintenance cycles, or performing maintenance based on equipment condition rather than time. To achieve this task the TBM and CBM are being directed more towards a Reliability Centered Maintenance (RCM) program which is based on a number of parameters such as substation and breaker criticality to the system, maintenance history and diagnostic technologies to identify problems or indications when maintenance is required. The aim of this study is to develop an On-Line Monitoring Diagnostic Unit (OLMDU) for different classes of circuit breakers. The proposed OLMDU will carry out data acquisition and processing in order to extract the significant features in the data and then it will use artificial intelligence agents to achieve the proper diagnosis. Data compression techniques will be used to store the data for further analysis if needed.