Grant: Engage Grants Program
École Polytechnique de Montréal
$25,000.00
Optimization of two Surface Treaments (Plasma and Pluronic) for an Array of Gold Microelectrodes for Measuring Streaming Potentials on Articular Cartilage
EF 2017-18
Résumé
Biomomentum Inc. specializes in providing solutions for the biomechanical evaluation of tissues, biomaterialsand cartilage. The company develops and commercializes the Arthro-BSTTM, an arthroscopic probe used forprecise, non-destructive assessment of articular cartilage. Arthro-BSTTM measures streaming potentialsgenerated during compression of articular cartilage during an arthroscopic procedure and assesses itselectro-mechanical properties. To ensure reliable local streaming potential measurement by an individualmicroelectrode (37 microelectrodes, each with a geometric surface: 20µm x 80µm), a sophisticatedcurrent-voltage transducer is used. When the device is surgically introduced into the knee, small air bubblestend to form on the microelectrodes' surfaces, which create electrical fluctuations that cause a significant delaybefore the probe can perform useful measurements. Improving hydrophilicity (wettability) of themicroelectrode array should greatly reduce air bubble formation, which in turn should significantly reduceelectrical equilibration time during arthroscopy. In this project, two separate surface treatment methods will betested on the microelectrode array, both designed to increase wettablity: (i) Pluronic? brush-coating; (ii)Atmospheric pressure plasma-polymerization of organic films, known as plasma polymers.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
514084-2017
Name nom
Wertheimer, Michael
Department département
Génie physique
Organization id
64
Institution établissement
École Polytechnique de Montréal
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1901
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical technology
Research subject fr
Technologie biomédicale
Partie
1
Nb partie
1
Application title
Optimization of two Surface Treaments (Plasma and Pluronic) for an Array of Gold Microelectrodes for Measuring Streaming Potentials on Articular Cartilage
Keyword
NSERC
Application summary
Biomomentum Inc. specializes in providing solutions for the biomechanical evaluation of tissues, biomaterialsand cartilage. The company develops and commercializes the Arthro-BSTTM, an arthroscopic probe used forprecise, non-destructive assessment of articular cartilage. Arthro-BSTTM measures streaming potentialsgenerated during compression of articular cartilage during an arthroscopic procedure and assesses itselectro-mechanical properties. To ensure reliable local streaming potential measurement by an individualmicroelectrode (37 microelectrodes, each with a geometric surface: 20µm x 80µm), a sophisticatedcurrent-voltage transducer is used. When the device is surgically introduced into the knee, small air bubblestend to form on the microelectrodes' surfaces, which create electrical fluctuations that cause a significant delaybefore the probe can perform useful measurements. Improving hydrophilicity (wettability) of themicroelectrode array should greatly reduce air bubble formation, which in turn should significantly reduceelectrical equilibration time during arthroscopy. In this project, two separate surface treatment methods will betested on the microelectrode array, both designed to increase wettablity: (i) Pluronic? brush-coating; (ii)Atmospheric pressure plasma-polymerization of organic films, known as plasma polymers.