Our lab has developed a new wearable technology that unobtrusively generates storable electricity from the natural motion of walking. Currently, the device can extract up to 5W of electricity from each leg - enough to simultaneously power ten mobile phones. The device, which resembles an orthopedic knee brace, harvests energy from the end of a walker's stride, when the muscles are working to slow the movement of the leg. By aiding the body in decelerating the leg, the effort of the user is decreased and storable energy is harvested in much the same way hybrid cars recycle energy from braking.
Currently, the device uses knee-angle and speed of movement to determine at what point in the stride to harvest energy. However, we propose to control the device with the muscle activity of the user. Using electrode sensors that indicate when muscles are contracting, we can tap into the user's nervous system and naturally integrate our device and the user. We believe this control system will harvest more energy from the body, be more comfortable for the user, and be more adaptable to changing environments and movements.
To develop the control system we must, i) determine the ideal muscles to use for device control, ii) determine the optimal times during a stride to harvest energy and how these times relate to muscle activity, iii) determine how the level of muscle activity should relate to the applied resistance of the device, and finally iv) assess the new muscle activity controlled device in terms of power generation, user acceptability, and adaptability.
Our device has the potential to revolutionize the meaning of portable power. The applications for such a device are vast, from powering vital communication equipment for soldiers and rescue workers to powering medical devices such as drug-pumps and prostheses. The restricting weight and limited working time of battery power can be overcome by granting humans the ability to serve as their own renewable power source.
Programme
Vanier Canada Graduate Scholarships - Doctoral
Bénéficiaire
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
405707-2011
Name nom
Selinger, Jessica
Department département
Biomedical Physiology and Kinesiology
Organization id
5
Institution établissement
Simon Fraser University
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2011
Award amount
50000
Program id
VCGS
Program name en
Vanier Canada Graduate Scholarships - Doctoral
Program name fr
Bourses d'études supérieures du Canada Vanier - Doctorat
Group en
Training programs
Group fr
Programmes de bourse
Committee code
1082
Committee name en
Vanier Selection Committee
Committee name fr
Comité de sélection Vanier
Area of application code
9999
Area of application group en
Not available
Area of application group fr
Non disponible
Area of application en
Not available
Area of application fr
Non disponible
Research subject code
5502
Research subject group en
Animal biology
Research subject group fr
Biologie animale
Research subject en
Kinesiology
Research subject fr
Kinésiologie
Partie
0
Application title
Development of a myoelectric control system for a knee-mounted biomechanical energy harvester
Keyword
NSERC
Application summary
Our lab has developed a new wearable technology that unobtrusively generates storable electricity from the natural motion of walking. Currently, the device can extract up to 5W of electricity from each leg - enough to simultaneously power ten mobile phones. The device, which resembles an orthopedic knee brace, harvests energy from the end of a walker's stride, when the muscles are working to slow the movement of the leg. By aiding the body in decelerating the leg, the effort of the user is decreased and storable energy is harvested in much the same way hybrid cars recycle energy from braking.
Currently, the device uses knee-angle and speed of movement to determine at what point in the stride to harvest energy. However, we propose to control the device with the muscle activity of the user. Using electrode sensors that indicate when muscles are contracting, we can tap into the user's nervous system and naturally integrate our device and the user. We believe this control system will harvest more energy from the body, be more comfortable for the user, and be more adaptable to changing environments and movements.
To develop the control system we must, i) determine the ideal muscles to use for device control, ii) determine the optimal times during a stride to harvest energy and how these times relate to muscle activity, iii) determine how the level of muscle activity should relate to the applied resistance of the device, and finally iv) assess the new muscle activity controlled device in terms of power generation, user acceptability, and adaptability.
Our device has the potential to revolutionize the meaning of portable power. The applications for such a device are vast, from powering vital communication equipment for soldiers and rescue workers to powering medical devices such as drug-pumps and prostheses. The restricting weight and limited working time of battery power can be overcome by granting humans the ability to serve as their own renewable power source.