Grant: Discovery Grants Program - Individual

Carleton University

$21,000.00

Fire Performance of HSS Steel Connections

EF 2015-16

Résumé
Background: Fires can cause elevated temperature that can have adverse impact on the building elements and systems. Steel connections are vital and essential components of any steel structure. Observations from fires confirm that connections have considerable effect on the survival time of structural members due to their role in distributing forces. Hollow Steel Sections HSS are known to absorb heat energy at higher rates than thick steel sections, causing earlier yielding to occur. In a fire event, restrained steel beams can heat up quickly and cause lateral thrust on supporting columns. It is likely that columns fail because of this thrust, and not necessarily because of the elevated temperatures. Objectives: The proposed research aims to examine and evaluate, under fire conditions, the performance of existing HSS-to-HSS extended end-plate moment connections and work towards introducing a new connection capable of absorbing or redirecting the lateral thrust. Scientific approach: Using medium- and full-scale experiments, the performance of current and proposed HSS-to-HSS extended end-plate moment connections in fire conditions will be assessed. The proposed research focuses on how to utilize the catenary action in fire in order to improve the fire performance of restrained steel beams. ABAQUS finite element model will be used to analyze the couple effect of thermal and structural performance. Both design fires (for commercial and industrial type occupancies) as well as standard time-temperature profiles will be applied to the connections using a newly constructed fire facility at Carleton University's. The research is expected to advance the understanding of fire behaviour of the commonly used steel connections (not isolated connections), and propose an advanced connection that can enhance the stability in the event of fire. The results will be used to produce a fire resistance design method of beam-to-column connections.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
371673-2013
Name nom
Zalok, Ehab
Department département
Civil and Environmental Engineering
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2013
Award amount
21000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1509
Committee name en
Civil, Industrial and Systems Engineering
Committee name fr
Génie civil, industriel et des systèmes
Area of application code
9999
Area of application group en
Not available
Area of application group fr
Non disponible
Area of application en
Not available
Area of application fr
Non disponible
Research subject code
1000
Research subject group en
Civil engineering
Research subject group fr
Génie civil
Research subject en
Civil engineering
Research subject fr
Génie civil
Partie
3
Nb partie
5
Application title
Fire Performance of HSS Steel Connections
Keyword
NSERC
Application summary
Background: Fires can cause elevated temperature that can have adverse impact on the building elements and systems. Steel connections are vital and essential components of any steel structure. Observations from fires confirm that connections have considerable effect on the survival time of structural members due to their role in distributing forces. Hollow Steel Sections HSS are known to absorb heat energy at higher rates than thick steel sections, causing earlier yielding to occur. In a fire event, restrained steel beams can heat up quickly and cause lateral thrust on supporting columns. It is likely that columns fail because of this thrust, and not necessarily because of the elevated temperatures. Objectives: The proposed research aims to examine and evaluate, under fire conditions, the performance of existing HSS-to-HSS extended end-plate moment connections and work towards introducing a new connection capable of absorbing or redirecting the lateral thrust. Scientific approach: Using medium- and full-scale experiments, the performance of current and proposed HSS-to-HSS extended end-plate moment connections in fire conditions will be assessed. The proposed research focuses on how to utilize the catenary action in fire in order to improve the fire performance of restrained steel beams. ABAQUS finite element model will be used to analyze the couple effect of thermal and structural performance. Both design fires (for commercial and industrial type occupancies) as well as standard time-temperature profiles will be applied to the connections using a newly constructed fire facility at Carleton University's. The research is expected to advance the understanding of fire behaviour of the commonly used steel connections (not isolated connections), and propose an advanced connection that can enhance the stability in the event of fire. The results will be used to produce a fire resistance design method of beam-to-column connections.