Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Collaborative Research and Development Grants

University of Alberta

$10,400.00

Partially grouted masonry walls: experimental response & ANN/FEA analysis models

EF 2021-22

Résumé
Reinforced masonry (RM) shear walls are often used as the primary load-resisting system against lateral loads in low- and medium-rise masonry structures. RM walls can be fully grouted (FG) or partially grouted (PG) with the latter option being generally more economical, and thus, widely used in the masonry industry. While expected to remain sufficiently stiff under service loads, a masonry shear wall is expected to exhibit a ductile response under lateral load at the ultimate state. However, if the behaviour is shear-critical, failure may occur suddenly and lead to catastrophic loss of life and property. Recent studies have shown that current design provisions do not predict the shear strength of PG shear walls with consistent accuracy over the range of design variables commonly found in practice. Research has shown that in some cases, design provisions may lead to potentially unsafe designs. To develop safe, accurate, and robust design methods for the shear and flexural strength of PG walls, the Canadian Concrete Masonry Producers Association (CCMPA) and Canada Masonry Design Centre (CMDC) are not-for-profit industry associations representing the national technical interests of masonry contractors and block manufacturers, respectively, are interested in undertaking an analytical and experimental program in collaboration with the University of Alberta. Analysis models for the structural response of masonry PG walls will be developed using results from experimental testing, finite-element (FE) modelling, artificial neural networks (ANN), and mechanics-based strength formulations. The analysis model will permit an improved understanding of the mechanics underlying the behaviour of PG walls. The experimental tests will allow to examine the influence of critical design variables, calibrate the analysis models, and advance the existing knowledge on the structural response of PG walls. The rational design methods for PG walls developed in this research project will benefit the masonry industry and contractors by allowing the construction of safer and more economic PG walls.
Programme
Collaborative Research and Development Grants
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
514260-2017
Name nom
Cruz Noguez, Carlos
Department département
Civil and Environmental Engineering
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2021
Competition year année de concours
2017
Award amount
10400
Program id
CRDPJ
Program name en
Collaborative Research and Development Grants
Program name fr
Subventions de recherche et développement coopérative
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
600
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Construction, urban and rural planning
Area of application fr
Construction, urbanisme et aménagement rural
Research subject code
1103
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Concrete structures
Research subject fr
Structures en béton
Installment
inst:6
Partie
1
Nb partie
6
Application title
Partially grouted masonry walls: experimental response & ANN/FEA analysis models
Keyword
NSERC
Application summary
Reinforced masonry (RM) shear walls are often used as the primary load-resisting system against lateral loads in low- and medium-rise masonry structures. RM walls can be fully grouted (FG) or partially grouted (PG) with the latter option being generally more economical, and thus, widely used in the masonry industry. While expected to remain sufficiently stiff under service loads, a masonry shear wall is expected to exhibit a ductile response under lateral load at the ultimate state. However, if the behaviour is shear-critical, failure may occur suddenly and lead to catastrophic loss of life and property. Recent studies have shown that current design provisions do not predict the shear strength of PG shear walls with consistent accuracy over the range of design variables commonly found in practice. Research has shown that in some cases, design provisions may lead to potentially unsafe designs. To develop safe, accurate, and robust design methods for the shear and flexural strength of PG walls, the Canadian Concrete Masonry Producers Association (CCMPA) and Canada Masonry Design Centre (CMDC) are not-for-profit industry associations representing the national technical interests of masonry contractors and block manufacturers, respectively, are interested in undertaking an analytical and experimental program in collaboration with the University of Alberta. Analysis models for the structural response of masonry PG walls will be developed using results from experimental testing, finite-element (FE) modelling, artificial neural networks (ANN), and mechanics-based strength formulations. The analysis model will permit an improved understanding of the mechanics underlying the behaviour of PG walls. The experimental tests will allow to examine the influence of critical design variables, calibrate the analysis models, and advance the existing knowledge on the structural response of PG walls. The rational design methods for PG walls developed in this research project will benefit the masonry industry and contractors by allowing the construction of safer and more economic PG walls.