Grant: Discovery Grants Program - Individual
University of Calgary
$21,040.00
Non-mechanical continuous flow micropumps for biomedical applications
EF 2015-16
Résumé
This research will focus on investigating non-mechanical micropumping methods for making small devices to pump fluid in bio-medical devices. The fluid will be pumped using electricity through small microneedles. The chosen area of research is specifically aimed at improving patient care by removing the need for hypodermic syringes and providing the path into automated drug delivery methods. Specifically, AC electrokinetic techniques will be investigated for pumping fluids through custom made silicon microneedle arrays. Microneedle arrays penetrate the upper part of skin, avoiding the nerves, allowing for practically painless skin penetration. The investigation will focus on the need to create small, low power, reliable devices. Traditional methods of fabricating the devices will be used initially, such as photolithography, coupled with computer simulations to design optimal devices. During the later stages of the research, fabrication will transition to alternate technologies, such as commercial silicon chip manufacturing processes and laser micromachining.
To achieve these goals, a series of experimental testing, simulation and design optimization of AC electrokinetic micropumps will be conducted. The experimental data will be compared with simulation data and the simulation models modified accordingly, iteratively leading to new designs of micropumps. The research methodology will involve investigating several electrokinetic micropumping factors, such as voltages and currents applied; temperature issues such as damage to the fluid solution, fluid properties within microfluidic channels and also the geometry of the electrode arrays and the microfludics channels themselves. These devices will form an integral part of a biomedical engineering solution for healthcare.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
386864-2012
Name nom
Dalton, Colin
Department département
Electrical and Computer Engineering
Organization id
11
Institution établissement
University of Calgary
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2012
Award amount
21040
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2500
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electrical and electronic engineering
Research subject fr
Génie électrique et électronique
Partie
4
Nb partie
5
Application title
Non-mechanical continuous flow micropumps for biomedical applications
Keyword
NSERC
Application summary
This research will focus on investigating non-mechanical micropumping methods for making small devices to pump fluid in bio-medical devices. The fluid will be pumped using electricity through small microneedles. The chosen area of research is specifically aimed at improving patient care by removing the need for hypodermic syringes and providing the path into automated drug delivery methods. Specifically, AC electrokinetic techniques will be investigated for pumping fluids through custom made silicon microneedle arrays. Microneedle arrays penetrate the upper part of skin, avoiding the nerves, allowing for practically painless skin penetration. The investigation will focus on the need to create small, low power, reliable devices. Traditional methods of fabricating the devices will be used initially, such as photolithography, coupled with computer simulations to design optimal devices. During the later stages of the research, fabrication will transition to alternate technologies, such as commercial silicon chip manufacturing processes and laser micromachining.
To achieve these goals, a series of experimental testing, simulation and design optimization of AC electrokinetic micropumps will be conducted. The experimental data will be compared with simulation data and the simulation models modified accordingly, iteratively leading to new designs of micropumps. The research methodology will involve investigating several electrokinetic micropumping factors, such as voltages and currents applied; temperature issues such as damage to the fluid solution, fluid properties within microfluidic channels and also the geometry of the electrode arrays and the microfludics channels themselves. These devices will form an integral part of a biomedical engineering solution for healthcare.