Grant: Idea to Innovation
University of Waterloo
$125,000.00
Ultra-stable liquid-nitrogen-free holder for high-resolution cryo-electron microscopy - Phase I
EF 2019-20
Résumé
One important technical problem in cryo-EM, when trying to attain atomically resolved 3D structures of frozen hydrated specimens, is the negative effect on the resolution due to vibrations and sample drift. Cryo-EM holders have so far relied on the application of a dewar that has to be filled with LN to cool down the specimen to temperatures below -145 C. However, the use of LN is often inconvenient. Water crystallization inside the dewar and relatively hot spots may induce vibration through LN bubbling, limiting the attainable spatial resolution. Significant user expertise is often required to circumvent these issues and perform single particle cryo-EM measurements with atomic spatial resolution, i.e. < 0.3 nm. In addition, LN spills limit the attainable single tilt angle required to recover 3D information in cryo-electron tomography studies.Waterloo researchers have designed a cryo-EM holder that does not require the use of LN, and therefore avoids the constant refilling step inherent with this method and all aforementioned issues associated with the use of LN. The design is capable of providing equal or lower sample temperatures than the current state of the art, with the additional benefit of minimal to no vibrations, no sample drift caused by LN evaporation, extended (basically unlimited) cooling periods, and any arbitrary single axis tilting.This technology has been assigned to the University of Waterloo (Waterloo) through its Commercialization Office (WatCo), which filed a US provisional patent (Petruk and Sciaini; USPTO 62/801,327, February 5th, 2019). The proposed cryogenic approach has the potential to become the method of choice in the performance of high-resolution cryo-EM work without the need of expensive cryo-TEMs with autoloaders.
Programme
Idea to Innovation
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
545135-2019
Name nom
Sciaini, Germán
Department département
Chemistry
Organization id
33
Institution établissement
University of Waterloo
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2019
Award amount
125000
Program id
I2IPJ
Program name en
Idea to Innovation
Program name fr
De l'idée à l'innovation
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
7000
Research subject group en
Other studies in natural sciences and engineering
Research subject group fr
Autres études en sciences naturelles et en génie
Research subject en
Other studies in natural sciences and engineering
Research subject fr
Autres études en sciences naturelles et en génie
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
Ultra-stable liquid-nitrogen-free holder for high-resolution cryo-electron microscopy - Phase I
Keyword
NSERC
Application summary
One important technical problem in cryo-EM, when trying to attain atomically resolved 3D structures of frozen hydrated specimens, is the negative effect on the resolution due to vibrations and sample drift. Cryo-EM holders have so far relied on the application of a dewar that has to be filled with LN to cool down the specimen to temperatures below -145 C. However, the use of LN is often inconvenient. Water crystallization inside the dewar and relatively hot spots may induce vibration through LN bubbling, limiting the attainable spatial resolution. Significant user expertise is often required to circumvent these issues and perform single particle cryo-EM measurements with atomic spatial resolution, i.e. < 0.3 nm. In addition, LN spills limit the attainable single tilt angle required to recover 3D information in cryo-electron tomography studies.Waterloo researchers have designed a cryo-EM holder that does not require the use of LN, and therefore avoids the constant refilling step inherent with this method and all aforementioned issues associated with the use of LN. The design is capable of providing equal or lower sample temperatures than the current state of the art, with the additional benefit of minimal to no vibrations, no sample drift caused by LN evaporation, extended (basically unlimited) cooling periods, and any arbitrary single axis tilting.This technology has been assigned to the University of Waterloo (Waterloo) through its Commercialization Office (WatCo), which filed a US provisional patent (Petruk and Sciaini; USPTO 62/801,327, February 5th, 2019). The proposed cryogenic approach has the potential to become the method of choice in the performance of high-resolution cryo-EM work without the need of expensive cryo-TEMs with autoloaders.