Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Alliance Grants

York University

$25,000.00

Microfluidic PFAS Sensor based on Molecularly Imprinted Polymer and Fluorescent Detection

EF 2024-25

Résumé
Through collaborative efforts with Sixth Wave Inc. (SIXW) under NSERC and MITACS projects, innovative methodologies for Cell Imprinted Polymers (CIPs) specific to bacteria and bacteriophages have been developed and patented. These CIPs have been integrated into versatile biosensing interfaces using fluorescent magnetic microparticles (MMPs) and microwires (MWs), achieving a limit of detection (LOD) of 102 CFU/mL for Escherichia coli (E. coli) capturing and detection. Building on these achievements, a portable version of the device has been developed for pathogen detection in environmental water, enhancing the practicality and versatility of the biosensing technology. The current international collaboration aims to develop, characterize, and deploy a portable imprinted polymer-based microfluidic fluorometric sensor for detecting Per- and Polyfluoroalkyl Substances (PFAS) in (waste)water. The objectives include optimizing Molecularly Imprinted Polymers (MIPs) for specific PFAS capturing and developing a portable MIP-based microfluidic sensor for PFAS detection. The outcomes of this project include the development of a portable platform technology for PFAS detection, training of a postdoc in the PFAS sensor sector, initiating an international collaboration, completion of data for a second patent, and publication of two new journal papers. The collaboration with Prof. Virender K. Sharma's team will provide expertise in the remediation of PFAS and access to water samples and testing facilities, benefiting the postdoc training experience and the Canadian biotechnology sector. The global importance and benefit to Canada lie in addressing PFAS contamination concerns, safeguarding water resources, and positioning Canada as a leader in addressing environmental challenges. The project aims to develop a beta prototype of the PFAS sensor for validation with end-users in Canada and the USA, fostering collaborations for potential commercialization.
Programme
Alliance Grants
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
592396-2023
Name nom
Rezai, Pouya P
Department département
Mechanical Engineering
Organization id
38
Institution établissement
York University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2023
Award amount
25000
Program id
ALLRP
Program name en
Alliance Grants
Program name fr
Subventions Alliance
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Microfluidic PFAS Sensor based on Molecularly Imprinted Polymer and Fluorescent Detection
Keywords
fluorescent detection; microfluidics; molecularly imprinted polymers; per- and polyfluoroalkyl substances; pfas; point of need detection; portable sensor; sensor; water monitoring
Application summary
Through collaborative efforts with Sixth Wave Inc. (SIXW) under NSERC and MITACS projects, innovative methodologies for Cell Imprinted Polymers (CIPs) specific to bacteria and bacteriophages have been developed and patented. These CIPs have been integrated into versatile biosensing interfaces using fluorescent magnetic microparticles (MMPs) and microwires (MWs), achieving a limit of detection (LOD) of 102 CFU/mL for Escherichia coli (E. coli) capturing and detection. Building on these achievements, a portable version of the device has been developed for pathogen detection in environmental water, enhancing the practicality and versatility of the biosensing technology. The current international collaboration aims to develop, characterize, and deploy a portable imprinted polymer-based microfluidic fluorometric sensor for detecting Per- and Polyfluoroalkyl Substances (PFAS) in (waste)water. The objectives include optimizing Molecularly Imprinted Polymers (MIPs) for specific PFAS capturing and developing a portable MIP-based microfluidic sensor for PFAS detection. The outcomes of this project include the development of a portable platform technology for PFAS detection, training of a postdoc in the PFAS sensor sector, initiating an international collaboration, completion of data for a second patent, and publication of two new journal papers. The collaboration with Prof. Virender K. Sharma's team will provide expertise in the remediation of PFAS and access to water samples and testing facilities, benefiting the postdoc training experience and the Canadian biotechnology sector. The global importance and benefit to Canada lie in addressing PFAS contamination concerns, safeguarding water resources, and positioning Canada as a leader in addressing environmental challenges. The project aims to develop a beta prototype of the PFAS sensor for validation with end-users in Canada and the USA, fostering collaborations for potential commercialization.