Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Engage Grants Program

University of British Columbia

$24,954.00

Identifying and removing low quality seismocardiogram cycles

EF 2017-18

Résumé
Cardiovascular diseases (CVDs) affect the lives of 1.6 million Canadians, and are the second leading cause ofdeath in Canada. CVDs cost the Canadian economy more than $20 Billion annually. Heart Force Medical Inc.(HFM) is a Vancouver-based company developing software and hardware technologies for the noninvasivecardiac monitoring to prevent and diagnose CVDs. In particular, HFM's proprietary technology measures heartvibration, which is referred as the seismocardiogram (SCG). SCGs can be captured by placing an accelerometeron the sternum, and provide information about mechanical aspects of the heart. Due to the inherent sensitivityof the SCG signal to motion artifacts caused by respiration or body movements, sophisticated algorithms haveto be developed to remove or minimize the effect of these artifacts. Another source of inadequate reliability ofthe SCG signal is the inappropriate placement of the accelerometer sensor on the sternum. In these situations,the SCG signals are of low quality (LQ) and the extraction of cardiac information is unreliable. Therefore, thepurpose of this proposal is to develop an algorithm that (1) can accommodate motion artifacts, and (2) canautomatically identify and remove LQ SCG cycles prior to analysis. Such an algorithm has to learn themorphology of recognizable and acceptable SCG cardiac cycles and discard those cycles when important datacannot be extracted. This step is crucial in the overall electromechanical assessment of cardiac function. Thedeveloped algorithm will be deployed in relevant HFM devices to increase their accuracy, reliability, andusability to evaluate cardiac performance.
Programme
Engage Grants Program
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
513399-2017
Name nom
Hodgson, Antony
Department département
Mechanical Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2017
Competition year année de concours
2017
Award amount
24954
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1554
Committee name en
Pacific Internal Decision Committee
Committee name fr
Comité de décision interne pour le Pacifique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
1
Nb partie
1
Application title
Identifying and removing low quality seismocardiogram cycles
Keyword
NSERC
Application summary
Cardiovascular diseases (CVDs) affect the lives of 1.6 million Canadians, and are the second leading cause ofdeath in Canada. CVDs cost the Canadian economy more than $20 Billion annually. Heart Force Medical Inc.(HFM) is a Vancouver-based company developing software and hardware technologies for the noninvasivecardiac monitoring to prevent and diagnose CVDs. In particular, HFM's proprietary technology measures heartvibration, which is referred as the seismocardiogram (SCG). SCGs can be captured by placing an accelerometeron the sternum, and provide information about mechanical aspects of the heart. Due to the inherent sensitivityof the SCG signal to motion artifacts caused by respiration or body movements, sophisticated algorithms haveto be developed to remove or minimize the effect of these artifacts. Another source of inadequate reliability ofthe SCG signal is the inappropriate placement of the accelerometer sensor on the sternum. In these situations,the SCG signals are of low quality (LQ) and the extraction of cardiac information is unreliable. Therefore, thepurpose of this proposal is to develop an algorithm that (1) can accommodate motion artifacts, and (2) canautomatically identify and remove LQ SCG cycles prior to analysis. Such an algorithm has to learn themorphology of recognizable and acceptable SCG cardiac cycles and discard those cycles when important datacannot be extracted. This step is crucial in the overall electromechanical assessment of cardiac function. Thedeveloped algorithm will be deployed in relevant HFM devices to increase their accuracy, reliability, andusability to evaluate cardiac performance.