Grant: Discovery Grants Program - Individual
University of British Columbia
$33,000.00
Micro-acousto-electro-mechanical systems (MAEMS). A systemic approach for a pervasive ultrasound
EF 2022-23
Résumé
Ultrasound (US) imaging systems provide significant advantages that justify why they remain the dominant clinical imaging procedure (more than 25%), and the use of ultrasound outside the medical field, in non-destructive testing (NDT), industrial (e.g. automotive) or consumer applications (e.g. for haptic interfaces). We have developed a novel, low-cost, polymer based microfabrication technology for Capacitive Micromachined Ultrasonic Transducer (CMUT) arrays, with a fabrication cycle of days, and competitive transducer performance. The present research program propagates the benefits of this technology, in a structured way, to the various architectural layers of an ultrasound system, to address most of the present challenges in US imaging and align with a vision where ultrasound will become ubiquitous. We entitle the program "from MEMS to MAEMS", to emphasize on the expansion of already pervasive MEMS (Micro-electro-mechanical systems) into a wider MAEMS (Micro-acousto-electro-mechanical systems) realm. Several major challenges in US systems are addressed in a combined and novel manners, at different coupled levels: technology development, device innovations, electronic interface, hybrid integration and assembly, array signal processing and intelligent data fusion. Low-cost, even disposable US transducers and systems are achievable through low-cost and green transducers microfabrication, combined with mostly digital electronic interfaces and hybrid assembly solutions (3D printing). Individual-level customization, impossible in classic Si-foundries manufacturing, is possible through the rapid microfabrication cycle (1-2 days), combined with programmable digital electronics and a fast and concurrent design and simulation cycle using extracted reduced-order macromodels (ROMs). High performance imaging will be obtained through large area US arrays on flexible substrates (conformal US), enabling 3D imaging, multi-imaging fusion (e.g. X-Ray + US or opto-acoustic) that relies on the optical and X-Ray transparency of the polymer used, and adaptive beamforming based on data fusion, using information from extra curvature/position sensors embedded in the array. The interconnection/communication bottleneck for a large number of channels are addressed through stacked assemblies of polyCMUT arrays and electronics, digital bitstreams channels, combined with compressive sensing. Advanced signal processing applications will combine super-resolution imaging algorithms with the electrical programmability of polyCMUT (through variable DC bias voltages). The integrated path in designing US systems presents unique opportunities for optimizations and novelties through coupling between different system layers. Two main applications are targeted, to validate the power of our approach: a low-cost conformal US system for biomedical imaging (heart monitoring) and a large area imaging system for NDT of CFRP plates used in the aerospace industry.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
RGPIN-2022-05302
Name nom
Cretu, Edmond
Department département
Electrical and Computer Engineering - Electrical and Computer Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2022
Competition year année de concours
2022
Award amount
33000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
2500
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Electrical and electronic engineering
Research subject fr
Génie électrique et électronique
Installment
inst:1
Partie
1
Nb partie
5
Application title
Micro-acousto-electro-mechanical systems (MAEMS). A systemic approach for a pervasive ultrasound
Application summary
Ultrasound (US) imaging systems provide significant advantages that justify why they remain the dominant clinical imaging procedure (more than 25%), and the use of ultrasound outside the medical field, in non-destructive testing (NDT), industrial (e.g. automotive) or consumer applications (e.g. for haptic interfaces). We have developed a novel, low-cost, polymer based microfabrication technology for Capacitive Micromachined Ultrasonic Transducer (CMUT) arrays, with a fabrication cycle of days, and competitive transducer performance. The present research program propagates the benefits of this technology, in a structured way, to the various architectural layers of an ultrasound system, to address most of the present challenges in US imaging and align with a vision where ultrasound will become ubiquitous. We entitle the program "from MEMS to MAEMS", to emphasize on the expansion of already pervasive MEMS (Micro-electro-mechanical systems) into a wider MAEMS (Micro-acousto-electro-mechanical systems) realm. Several major challenges in US systems are addressed in a combined and novel manners, at different coupled levels: technology development, device innovations, electronic interface, hybrid integration and assembly, array signal processing and intelligent data fusion. Low-cost, even disposable US transducers and systems are achievable through low-cost and green transducers microfabrication, combined with mostly digital electronic interfaces and hybrid assembly solutions (3D printing). Individual-level customization, impossible in classic Si-foundries manufacturing, is possible through the rapid microfabrication cycle (1-2 days), combined with programmable digital electronics and a fast and concurrent design and simulation cycle using extracted reduced-order macromodels (ROMs). High performance imaging will be obtained through large area US arrays on flexible substrates (conformal US), enabling 3D imaging, multi-imaging fusion (e.g. X-Ray + US or opto-acoustic) that relies on the optical and X-Ray transparency of the polymer used, and adaptive beamforming based on data fusion, using information from extra curvature/position sensors embedded in the array. The interconnection/communication bottleneck for a large number of channels are addressed through stacked assemblies of polyCMUT arrays and electronics, digital bitstreams channels, combined with compressive sensing. Advanced signal processing applications will combine super-resolution imaging algorithms with the electrical programmability of polyCMUT (through variable DC bias voltages). The integrated path in designing US systems presents unique opportunities for optimizations and novelties through coupling between different system layers. Two main applications are targeted, to validate the power of our approach: a low-cost conformal US system for biomedical imaging (heart monitoring) and a large area imaging system for NDT of CFRP plates used in the aerospace industry.