Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of Calgary

$20,000.00

""Improving the speed, accuracy, and movement range of piezoelectric scanners in scanning probe microscopy""

EF 2015-16

Résumé
Piezoelectric scanner plays a vital role in the scanning probe microscope (SPM). Despite all the qualities piezoceramics have that make them the best materials for precision positioning, they are far from being ideal in the motion they generate. The ability of an SPM to eventually become an economically viable nano-fabrication tool relies on the ability of the piezoelectric actuator to move at high speed and through a large range without compromising its positioning accuracy and repeatability. At present, both aspects of performance are limited by the linearity range of piezoceramics. In addition, existing piezoelectric actuators are susceptible to noise at low speed when they are commanded to hold a constant position. Noise due to external disturbance, piezoelectic creep and thermal drift are major causes of position inaccuracy at low speeds. To address the performance issues of a piezoelectric scanner, we have made some progress in the past in identifying problems and forming solutions. Most importantly, we have constructed a micromechanics model that can capture the polarization domain switching process. Consequently, it can predict the nonlinear behavior of the scanner in a more general, complete, and accurate manner. It employs physical parameters that can be correlated to physical measurements. The objective of the proposed research is to take our existing work to the next level, that is, to combine the model with controller design to better control the scanner movement. Specific goals include: 1) Developing a reduced order model that can bridge the gap between a full micromechanics model and a model with real time tractability. 2) Developing a self-sensing strategy to assist real time model parameter estimation. 3) Developing an inversion control technique to compensate for the material nonlinearity to achieve improved position accuracy. 4) Developing an active damping technique to control the scanner vibration at high scanning rate. 5) Improving the quality of noise cancellation in the vibration isolator. Finally, performance improvement will be verified through experiments on a test-bed.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
203433-2012
Name nom
Sun, Qiao
Department département
Mechanical and Manufacturing Engineering
Organization id
11
Institution établissement
University of Calgary
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2012
Award amount
20000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
515
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Instrumentation technology
Area of application fr
Technologie de l'instrumentation
Research subject code
2109
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical systems and instrumentation
Research subject fr
Instrumentation et systèmes mécaniques
Partie
4
Nb partie
5
Application title
""Improving the speed, accuracy, and movement range of piezoelectric scanners in scanning probe microscopy""
Keyword
NSERC
Application summary
Piezoelectric scanner plays a vital role in the scanning probe microscope (SPM). Despite all the qualities piezoceramics have that make them the best materials for precision positioning, they are far from being ideal in the motion they generate. The ability of an SPM to eventually become an economically viable nano-fabrication tool relies on the ability of the piezoelectric actuator to move at high speed and through a large range without compromising its positioning accuracy and repeatability. At present, both aspects of performance are limited by the linearity range of piezoceramics. In addition, existing piezoelectric actuators are susceptible to noise at low speed when they are commanded to hold a constant position. Noise due to external disturbance, piezoelectic creep and thermal drift are major causes of position inaccuracy at low speeds. To address the performance issues of a piezoelectric scanner, we have made some progress in the past in identifying problems and forming solutions. Most importantly, we have constructed a micromechanics model that can capture the polarization domain switching process. Consequently, it can predict the nonlinear behavior of the scanner in a more general, complete, and accurate manner. It employs physical parameters that can be correlated to physical measurements. The objective of the proposed research is to take our existing work to the next level, that is, to combine the model with controller design to better control the scanner movement. Specific goals include: 1) Developing a reduced order model that can bridge the gap between a full micromechanics model and a model with real time tractability. 2) Developing a self-sensing strategy to assist real time model parameter estimation. 3) Developing an inversion control technique to compensate for the material nonlinearity to achieve improved position accuracy. 4) Developing an active damping technique to control the scanner vibration at high scanning rate. 5) Improving the quality of noise cancellation in the vibration isolator. Finally, performance improvement will be verified through experiments on a test-bed.