Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Vanier Canada Graduate Scholarships - Doctoral

University of British Columbia

$50,000.00

Rapid Endothelialization of Vascular Stents using Microelectromechanical Systems Technology

EF 2012-13

Résumé
Cardiovascular disease is the number one cause of death among Canadians. Every year thousands of Canadians undergo medical treatment in order to widen a narrowed or obstructed blood vessel. Narrowing of the blood vessels is caused by the build up of fatty particles that form on the vessel wall. Widening of the narrowed blood vessel is done by inserting a stent, a man-made tube, into the vessel at the place where the narrowing of the vessel has occurred. The stent is designed to widen the vessel by exerting pressure on the walls, and stopping the vessel walls from collapsing inwards. After the insertion of a vascular stent, biofouling and thrombosis, the growth of unwanted and hazardous cell tissue on the stent, could impede the adaptation of the body to the implanted stent, and presents a great risk to the patient's health, causing complications and occasionally death. We believe that a controlled surface charge applied on the surface of the stent, in conjunction with low-level mechanical vibrations of the stent structure, could reduce and even omit the formation of thrombosis cell tissue on the stent. It is also very likely that introduction of the low-level vibrations could help promote the growth of endothelial cells (the cells lining the walls of the blood vessels), increasing the adaptability of the implanted stent to its surrounding environment. To produce the surface charges and low-level vibrations, we are developing a multi-layered stent integrated with micro-scale actuators and the controlling circuitry. The stent is powered remotely by magnetic fields generated outside the body which induce electrical charges in the stent circuits. The actuators use this electrical energy to produce mechanical vibrations in the stent body. These vibrations will promote the growth of ECs on the stent surface, making it adaptable to the human body and thus promoting a rapid recovery. Successful completion of this research could greatly benefit the lives of many Canadians.
Programme
Vanier Canada Graduate Scholarships - Doctoral
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
405726-2011
Name nom
Khademolhosseini, Farzad
Department département
Mechanical Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2011
Award amount
50000
Program id
VCGS
Program name en
Vanier Canada Graduate Scholarships - Doctoral
Program name fr
Bourses d'études supérieures du Canada Vanier - Doctorat
Group en
Training programs
Group fr
Programmes de bourse
Committee code
1082
Committee name en
Vanier Selection Committee
Committee name fr
Comité de sélection Vanier
Area of application code
9999
Area of application group en
Not available
Area of application group fr
Non disponible
Area of application en
Not available
Area of application fr
Non disponible
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Partie
0
Application title
Rapid Endothelialization of Vascular Stents using Microelectromechanical Systems Technology
Keyword
NSERC
Application summary
Cardiovascular disease is the number one cause of death among Canadians. Every year thousands of Canadians undergo medical treatment in order to widen a narrowed or obstructed blood vessel. Narrowing of the blood vessels is caused by the build up of fatty particles that form on the vessel wall. Widening of the narrowed blood vessel is done by inserting a stent, a man-made tube, into the vessel at the place where the narrowing of the vessel has occurred. The stent is designed to widen the vessel by exerting pressure on the walls, and stopping the vessel walls from collapsing inwards. After the insertion of a vascular stent, biofouling and thrombosis, the growth of unwanted and hazardous cell tissue on the stent, could impede the adaptation of the body to the implanted stent, and presents a great risk to the patient's health, causing complications and occasionally death. We believe that a controlled surface charge applied on the surface of the stent, in conjunction with low-level mechanical vibrations of the stent structure, could reduce and even omit the formation of thrombosis cell tissue on the stent. It is also very likely that introduction of the low-level vibrations could help promote the growth of endothelial cells (the cells lining the walls of the blood vessels), increasing the adaptability of the implanted stent to its surrounding environment. To produce the surface charges and low-level vibrations, we are developing a multi-layered stent integrated with micro-scale actuators and the controlling circuitry. The stent is powered remotely by magnetic fields generated outside the body which induce electrical charges in the stent circuits. The actuators use this electrical energy to produce mechanical vibrations in the stent body. These vibrations will promote the growth of ECs on the stent surface, making it adaptable to the human body and thus promoting a rapid recovery. Successful completion of this research could greatly benefit the lives of many Canadians.