Grant: Engage Grants Program
University of Guelph
$25,000.00
Development of thickness shear mode biosensor for rapid detection of biological contamination in water
EF 2010-11
Résumé
The risk of drinking water contamination due to intentional and accidental contamination has increased the
need for diligence in the monitoring of drinking water supplies. To be useful, there is required implementation
which would provide rapid detection of biological contamination in drinking water supply systems. Routine
methods of culturing indicator microorganisms require considerable time (measured in days) and hence are of
limited value for this type of application.
Arshon Silicon Technology Incorporated (ASTINCO) is an Ontario company (Markham, Ontario) which is
one of the most active design firms in North America designing hardware, and software. In response to
growing demand for rapid detection devices, ASTINCO has focused on development of fast response, robust
and cost-effective sensors using Thickness Shear Mode (TSM) sensor, employing Quartz Crystal Microbalance
(QCM) technology, for a variety of applications including detection of biological contamination in drinking
water. The market for such a sensing device is world-wide and is in excess of $4 billion/year.
TSM acoustic sensors have been widely used to monitor the changes in mass and viscosity of the media in
contact with the sensor surface. The relationship between viscosity, and changes in the resonant frequency of a
quartz crystal has been used for different applications such as measuring the activity of various enzymes,
biological space reactions, etc.
TSM sensors have a number of advantages over similar technologies such as Surface Plasmon Resonance,
Immunoassay methods, and PCR. Specifically, TSMs have fast response time, high sensitivity, and excellent
precision as well as ease of use, and low cost. They can be used anywhere without a need for specific expertise
and hence their potenital application is widespread.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
408131-2010
Name nom
McBean, Edward
Department département
Engineering, School of
Organization id
24
Institution établissement
University of Guelph
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2010
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
702
Area of application group en
Transportation systems and services
Area of application group fr
Services et systèmes de transport
Area of application en
Water
Area of application fr
Maritime
Research subject code
3504
Research subject group en
Analytical chemistry
Research subject group fr
Chimie analytique
Research subject en
Bioanalytical chemistry
Research subject fr
Chimie bioanalytique
Partie
1
Nb partie
1
Application title
Development of thickness shear mode biosensor for rapid detection of biological contamination in water
Keyword
NSERC
Application summary
The risk of drinking water contamination due to intentional and accidental contamination has increased the
need for diligence in the monitoring of drinking water supplies. To be useful, there is required implementation
which would provide rapid detection of biological contamination in drinking water supply systems. Routine
methods of culturing indicator microorganisms require considerable time (measured in days) and hence are of
limited value for this type of application.
Arshon Silicon Technology Incorporated (ASTINCO) is an Ontario company (Markham, Ontario) which is
one of the most active design firms in North America designing hardware, and software. In response to
growing demand for rapid detection devices, ASTINCO has focused on development of fast response, robust
and cost-effective sensors using Thickness Shear Mode (TSM) sensor, employing Quartz Crystal Microbalance
(QCM) technology, for a variety of applications including detection of biological contamination in drinking
water. The market for such a sensing device is world-wide and is in excess of $4 billion/year.
TSM acoustic sensors have been widely used to monitor the changes in mass and viscosity of the media in
contact with the sensor surface. The relationship between viscosity, and changes in the resonant frequency of a
quartz crystal has been used for different applications such as measuring the activity of various enzymes,
biological space reactions, etc.
TSM sensors have a number of advantages over similar technologies such as Surface Plasmon Resonance,
Immunoassay methods, and PCR. Specifically, TSMs have fast response time, high sensitivity, and excellent
precision as well as ease of use, and low cost. They can be used anywhere without a need for specific expertise
and hence their potenital application is widespread.