Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of Manitoba

$28,000.00

Monitoring and controlling of power systems using phasor measurement data

EF 2014-15

Résumé
The main objective of the proposed research program is to develop new techniques to monitor and controlpower systems to maximize the use of available infrastructure and minimize risks of instabilities that can leadto major black/brown outs. The successful application of Phasor Measurement Units (PMUs) has made the realtime monitoring of power systems a reality. With the availability of the measurements taken across the powersystem, the industry now needs effective methods of using this data. The proposed research program willinvestigate two areas of fulfilling this need. For the purpose of monitoring, one needs efficient and accurate methods of extracting useful information that are meaningful to the system operators. Such meaningful information include whether the current operating state of the power system is secure, whether the power system is operating with sufficient margin of stability, and whether there any preventive actions available. Several projects under the proposed research program will be devoted to appropriate modeling of the power system and developing mathematical tools to produce such information to the system operator. The second level of utilizing the phasor measurement unit data is for Control. The technology of wide area measurements is very mature. Taking this technology to the next level, which is to control the devices using PMU measurements as feedback signals, require a quantum leap in technology. While the new technology offers additional degrees of freedom for controller design, the challenge is to develop control algorithms that can handle transport delays and are robust against loss of feedback signals. The novelty of this research is to develop controller design algorithms to utilize this degree of flexibility to achieve multiple system stability related objectives. The concepts of applying dynamic phasors for Sub-synchronous Resonance studies recently presented by my research group enable a new way of looking at the problem of Sub-synchronous Resonance screening. The proposed research program will also advance this idea by applying frequency domain techniques to analyze Sub-synchronous Resonance on Voltage Sourced Controller based systems.
Programme
Discovery Grants Program - Individual
Emplacement
Manitoba, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
249606-2011
Name nom
Annakkage, Udaya
Department département
Electrical and Computer Engineering
Organization id
19
Institution établissement
University of Manitoba
Province en
Manitoba
Province fr
Manitoba
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2011
Award amount
28000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1510
Committee name en
Electrical and Computer Engineering
Committee name fr
Génie électrique et informatique
Area of application code
304
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Electrical energy
Area of application fr
Énergie électrique
Research subject code
2501
Research subject group en
Electrical and electronic engineering
Research subject group fr
Génie électrique et électronique
Research subject en
Power systems
Research subject fr
Réseaux électriques
Partie
4
Nb partie
5
Application title
Monitoring and controlling of power systems using phasor measurement data
Keyword
NSERC
Application summary
The main objective of the proposed research program is to develop new techniques to monitor and controlpower systems to maximize the use of available infrastructure and minimize risks of instabilities that can leadto major black/brown outs. The successful application of Phasor Measurement Units (PMUs) has made the realtime monitoring of power systems a reality. With the availability of the measurements taken across the powersystem, the industry now needs effective methods of using this data. The proposed research program willinvestigate two areas of fulfilling this need. For the purpose of monitoring, one needs efficient and accurate methods of extracting useful information that are meaningful to the system operators. Such meaningful information include whether the current operating state of the power system is secure, whether the power system is operating with sufficient margin of stability, and whether there any preventive actions available. Several projects under the proposed research program will be devoted to appropriate modeling of the power system and developing mathematical tools to produce such information to the system operator. The second level of utilizing the phasor measurement unit data is for Control. The technology of wide area measurements is very mature. Taking this technology to the next level, which is to control the devices using PMU measurements as feedback signals, require a quantum leap in technology. While the new technology offers additional degrees of freedom for controller design, the challenge is to develop control algorithms that can handle transport delays and are robust against loss of feedback signals. The novelty of this research is to develop controller design algorithms to utilize this degree of flexibility to achieve multiple system stability related objectives. The concepts of applying dynamic phasors for Sub-synchronous Resonance studies recently presented by my research group enable a new way of looking at the problem of Sub-synchronous Resonance screening. The proposed research program will also advance this idea by applying frequency domain techniques to analyze Sub-synchronous Resonance on Voltage Sourced Controller based systems.