Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Research Tools and Instruments - Category 1 (<$150,000)

University of Alberta

$28,442.00

Magnetic Tracking Sensors for Open Surgery Evaluation, Ultrasound Multi-view Fusion, and Cardiac Modeling

EF 2014-15

Résumé
We would like to purchase one new magnetic tracking system which can accommodate a 16-sensor unit with an outer diameter of 1.5 mm to be used for two of the three projects, and a second 16-sensor unit with an outer diameter of 0.58 mm for the cardiac modeling project. The first project is a sensor-based open surgery activity analysis project where two instrumented surgical gloves will be used in order to record expert surgeons' performances during open surgical procedures and to compare their performance with those of novices during training. Our goal is to insert into two modified surgical gloves, ten small (~1.5 mm) magnetic sensors combined with strain gage sensors to measure the position of each finger in 6-D (position and orientation) and the forces applied to them. The use of a magnetic tracker is critical as methods that rely on a direct line of sight are impossible to use in open surgery due to visual occlusions. Once the data is acquired for various tasks, our goal is to use global features and a simple curvature/force correlation technique to perform a comparison to determine how close the performances of the trainees and the expert surgeons are. In the second project, we propose a method that relies on the same portable 6-D magnetic tracking system mounted on an ultrasound scanner (US) to perform image alignment. This tracking system will allow us to solve image alignment as it eliminates the constraints on image overlap and quality as the accuracy of the alignment obtained by the tracking system is far superior to the image resolution of a US sensor. In the third project, we are planning to use the same equipment but with smaller magnetic trackers (0.58 mm) to validate patient specific models of a heart and to extract dynamic model parameters by measuring live heart motion. The main idea is to use those sensors to track the position of key anatomical landmarks on the heart and then compare them with our simulation. The discrepancy will then be minimized by adjusting model parameters such as geometry and material properties which are difficult to evaluate ex-vivo.
Programme
Research Tools and Instruments - Category 1 (<$150,000)
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
472602-2015
Name nom
Boulanger, Pierre
Department département
Computing Science
Organization id
9
Institution établissement
University of Alberta
Province en
Alberta
Province fr
Alberta
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2015
Award amount
28442
Program id
EQPEQ
Program name en
Research Tools and Instruments - Category 1 (<$150,000)
Program name fr
Outils et instruments de recherche - catégorie 1 (<150 000$)
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1507
Committee name en
Computer Science
Committee name fr
Sciences informatiques
Area of application code
1211
Area of application group en
Advancement of knowledge
Area of application group fr
Avancement des connaissances
Area of application en
Medical and health sciences
Area of application fr
Sciences médicales et de la santé
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Partie
1
Nb partie
1
Application title
Magnetic Tracking Sensors for Open Surgery Evaluation, Ultrasound Multi-view Fusion, and Cardiac Modeling
Keyword
NSERC
Application summary
We would like to purchase one new magnetic tracking system which can accommodate a 16-sensor unit with an outer diameter of 1.5 mm to be used for two of the three projects, and a second 16-sensor unit with an outer diameter of 0.58 mm for the cardiac modeling project. The first project is a sensor-based open surgery activity analysis project where two instrumented surgical gloves will be used in order to record expert surgeons' performances during open surgical procedures and to compare their performance with those of novices during training. Our goal is to insert into two modified surgical gloves, ten small (~1.5 mm) magnetic sensors combined with strain gage sensors to measure the position of each finger in 6-D (position and orientation) and the forces applied to them. The use of a magnetic tracker is critical as methods that rely on a direct line of sight are impossible to use in open surgery due to visual occlusions. Once the data is acquired for various tasks, our goal is to use global features and a simple curvature/force correlation technique to perform a comparison to determine how close the performances of the trainees and the expert surgeons are. In the second project, we propose a method that relies on the same portable 6-D magnetic tracking system mounted on an ultrasound scanner (US) to perform image alignment. This tracking system will allow us to solve image alignment as it eliminates the constraints on image overlap and quality as the accuracy of the alignment obtained by the tracking system is far superior to the image resolution of a US sensor. In the third project, we are planning to use the same equipment but with smaller magnetic trackers (0.58 mm) to validate patient specific models of a heart and to extract dynamic model parameters by measuring live heart motion. The main idea is to use those sensors to track the position of key anatomical landmarks on the heart and then compare them with our simulation. The discrepancy will then be minimized by adjusting model parameters such as geometry and material properties which are difficult to evaluate ex-vivo.