Résumé
Currently, owing to advances in sensing techniques and analysing procedures, the most popular experimental
modal test for large structures is ambient vibration testing. Ambient vibration analysis leads to the essential
structural characteristic of buildings called modal properties: mode shapes, natural frequencies and damping
ratios. These information are essential to keep track of future changes in the integrity of a structure, serve as its
baseline and help monitoring health of structures. Ambient vibration test is performed during normal operation
of the structure, therefore there are different source of vibrations: wind, micro-tremors, human activities.
Existence of these numbers of vibration sources requires very careful analysis of the recorded weak signals to
be able to accurately derive modal properties. Current existing frequency and time domain methods have
shortcomings with regard to analysis of noisy signals, closely space modes and damping ratios. They are
complex to be used by engineers, and also their advantages and disadvantages are not clearly specified. The
goal of the proposed project is to develop a new mix frequency / time domain method to improve the modal
identification process. The goals of this project are summarized as follow:
i) Detailed literature review of exiting methods to clearly identify their pros and cons.
ii) To develop new algorithm that can deal with ambient signals with higher noise, allowing to use less
sensitive low-cost sensors.
iii) The developed algorithm should be able to handle the closely-spaced modes more efficiently.
iv) To develop a simple method for on-site verification of time records so that the technician can re-conduct the
test if a problem is detected.
This technology transfer is essential for Sensequake Company and engineering community around the world.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
491593-2015
Name nom
Legrand, Mathias
Department département
Mechanical Engineering
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2015
Competition year année de concours
2015
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1552
Committee name en
Quebec Internal Decision Committee
Committee name fr
Comité de décision interne pour le Québec
Area of application code
405
Area of application group en
Environment
Area of application group fr
Environnement
Area of application en
Modelling and mathematical simulation of natural processes
Area of application fr
Modélisation et simulation mathématique des processus naturels
Research subject code
2104
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Vibrations
Research subject fr
Vibrations
Partie
1
Nb partie
1
Application title
Ouput-only vibration analysis of buildings in operational conditions
Keyword
NSERC
Application summary
Currently, owing to advances in sensing techniques and analysing procedures, the most popular experimental
modal test for large structures is ambient vibration testing. Ambient vibration analysis leads to the essential
structural characteristic of buildings called modal properties: mode shapes, natural frequencies and damping
ratios. These information are essential to keep track of future changes in the integrity of a structure, serve as its
baseline and help monitoring health of structures. Ambient vibration test is performed during normal operation
of the structure, therefore there are different source of vibrations: wind, micro-tremors, human activities.
Existence of these numbers of vibration sources requires very careful analysis of the recorded weak signals to
be able to accurately derive modal properties. Current existing frequency and time domain methods have
shortcomings with regard to analysis of noisy signals, closely space modes and damping ratios. They are
complex to be used by engineers, and also their advantages and disadvantages are not clearly specified. The
goal of the proposed project is to develop a new mix frequency / time domain method to improve the modal
identification process. The goals of this project are summarized as follow:
i) Detailed literature review of exiting methods to clearly identify their pros and cons.
ii) To develop new algorithm that can deal with ambient signals with higher noise, allowing to use less
sensitive low-cost sensors.
iii) The developed algorithm should be able to handle the closely-spaced modes more efficiently.
iv) To develop a simple method for on-site verification of time records so that the technician can re-conduct the
test if a problem is detected.