Grant: Engage Grants Program
University of Saskatchewan
$25,000.00
Frosting of air-to-air membrane energy exchangers
EF 2012-13
Résumé
Buildings are an integral part of Canadian society and economy as Canadians spend over 90% of their time in
buildings. In Canada and other developed countries, buildings consume about 40% of the primary energy and
60% of this energy is consumed by heating, ventilating and air conditioning (HVAC) systems. Buildings that
provide Canadians with a comfortable and healthy place to work and live are essential for a healthy, prosperous
and sustainable nation.
Recent advances in energy-efficiency have reduced the amount of energy required to heat or cool buildings.
Major advances have been achieved in: (1) building envelope performance (e.g., better windows and
insulation) so that less heat needs to be added to or removed from buildings, and (2) HVAC system efficiency
(where a higher efficiency means that more heat can be added to or removed from the building with the same
energy input such as electricity or natural gas). An energy exchanger is a device that can recover excess heat
and moisture from the building exhaust air to precondition the air being supplied to the building, which reduces
the amount of energy required to heat or cool the building. In cold climates however, frost may form on the
surface of the energy exchanger, reducing the effectiveness of the device.
The aim of this NSERC Engage grant is to enhance the performance of air-to-air membrane energy recovery
ventilators (ERV) designed and manufactured by dPoint Technologies through research on the effects of
frosting conditions on the performance of the ERV. Over a 6 month period, testing will be done to determine
the weather conditions that cause frosting in dPoint's ERVs for Canadian applications. Tests will be carried out
on ERVs with different membranes to study the effects of the membrane on frosting. By understanding when
frosting occurs in an ERV and how to detect it, the energy efficiency of ERVs can be improved in cold
climates.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Saskatchewan, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
444203-2012
Name nom
Simonson, Carey
Department département
Mechanical Engineering
Organization id
16
Institution établissement
University of Saskatchewan
Province en
Saskatchewan
Province fr
Saskatchewan
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2012
Competition year année de concours
2012
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1555
Committee name en
Prairie Internal Decision Committee
Committee name fr
Comité de décision interne pour les Prairies
Area of application code
306
Area of application group en
Energy resources
Area of application group fr
Ressources d'énergie
Area of application en
Energy efficiency
Area of application fr
Efficacité énergétique
Research subject code
1804
Research subject group en
Chemical engineering
Research subject group fr
Génie chimique
Research subject en
Heat transfer
Research subject fr
Transfert de chaleur
Partie
1
Nb partie
1
Application title
Frosting of air-to-air membrane energy exchangers
Keyword
NSERC
Application summary
Buildings are an integral part of Canadian society and economy as Canadians spend over 90% of their time in
buildings. In Canada and other developed countries, buildings consume about 40% of the primary energy and
60% of this energy is consumed by heating, ventilating and air conditioning (HVAC) systems. Buildings that
provide Canadians with a comfortable and healthy place to work and live are essential for a healthy, prosperous
and sustainable nation.
Recent advances in energy-efficiency have reduced the amount of energy required to heat or cool buildings.
Major advances have been achieved in: (1) building envelope performance (e.g., better windows and
insulation) so that less heat needs to be added to or removed from buildings, and (2) HVAC system efficiency
(where a higher efficiency means that more heat can be added to or removed from the building with the same
energy input such as electricity or natural gas). An energy exchanger is a device that can recover excess heat
and moisture from the building exhaust air to precondition the air being supplied to the building, which reduces
the amount of energy required to heat or cool the building. In cold climates however, frost may form on the
surface of the energy exchanger, reducing the effectiveness of the device.
The aim of this NSERC Engage grant is to enhance the performance of air-to-air membrane energy recovery
ventilators (ERV) designed and manufactured by dPoint Technologies through research on the effects of
frosting conditions on the performance of the ERV. Over a 6 month period, testing will be done to determine
the weather conditions that cause frosting in dPoint's ERVs for Canadian applications. Tests will be carried out
on ERVs with different membranes to study the effects of the membrane on frosting. By understanding when
frosting occurs in an ERV and how to detect it, the energy efficiency of ERVs can be improved in cold
climates.