Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Travel Awards - Institute Community Support

University of Calgary

$1,000.00

Sit-to-stand testing can effectively measure orthostatic vitals and diagnose orthostatic hypotension when lower diagnostic cut-offs are used

EF 2016-17

Résumé
Background: Orthostatic hypotension (OH) is an important clinical finding when evaluating syncope and falls. OH is diagnosed based on a supine-to-standing test, however this test can be impractical in settings like the outpatient clinic where time and space are limited. An alternative is a sit-to-stand procedure; this test induces a milder orthostatic stress making conventional diagnostic cut-offs for OH difficult to reach. This study aimed to identify optimal blood pressure (BP) cut-offs to diagnose OH during sit-to-stand. Methods: This study was made up of patients and healthy subjects who presented to the Vanderbilt University Autonomic Dysfunction Center. BP was measured while supine, seated, and standing (for 5 minutes). BP change was calculated from 1) supine-to-standing and 2) seated-to-standing. OH was diagnosed by a supine-to-standing systolic BP drop greater than 20 mmHg or a diastolic BP drop greater than 10 mmHg. Receiver operator characteristic curves identified optimal sit-to-stand cut-offs and the area under the curve was calculated. Results: Amongst the 994 subjects, more had systolic OH (n=404[41%]) than diastolic OH (n=349[35%]). We found that a sit-to stand systolic BP drop greater than 15 mmHg had optimal test characteristics (sensitivity=79%; specificity=89%; positive predictive value=83%; negative predictive value=86%), as did a diastolic BP drop greater than 7 mmHg (sensitivity=85%; specificity=88%; positive predictive value=79%; negative predictive value=91%). Conclusions: A sit-to-stand maneuver with lower diagnostic cut-offs for OH provides a simple OH screening test. This may be of utility in multiple clinical environments where testing could quickly be done upon patient arrival at triage or while in the clinic waiting room.
Programme
Travel Awards - Institute Community Support
Bénéficiaire
Emplacement
Alberta, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
CIHR Funding Decisions Database

Tel que publié

Id
352391
Name
Shaw Brett H
Region
Alberta
Country
Canada
Orgtype
Institution Paid; Research Institution
Instname2
Circulatory and Respiratory Health
Theme2
Clinical
Prcname2
Institute of Circulatory and Respiratory Health
Projecttitle
Sit-to-stand testing can effectively measure orthostatic vitals and diagnose orthostatic hypotension when lower diagnostic cut-offs are used
Programtype2
Undefined
Orgnameinp2
University of Calgary
Cihramount2
$1,000
Cihrequipment2
$0
Programname2
Travel Awards - Institute Community Support
Keyworddelim
Ics Travel Awards
Abstract
Background: Orthostatic hypotension (OH) is an important clinical finding when evaluating syncope and falls. OH is diagnosed based on a supine-to-standing test, however this test can be impractical in settings like the outpatient clinic where time and space are limited. An alternative is a sit-to-stand procedure; this test induces a milder orthostatic stress making conventional diagnostic cut-offs for OH difficult to reach. This study aimed to identify optimal blood pressure (BP) cut-offs to diagnose OH during sit-to-stand. Methods: This study was made up of patients and healthy subjects who presented to the Vanderbilt University Autonomic Dysfunction Center. BP was measured while supine, seated, and standing (for 5 minutes). BP change was calculated from 1) supine-to-standing and 2) seated-to-standing. OH was diagnosed by a supine-to-standing systolic BP drop greater than 20 mmHg or a diastolic BP drop greater than 10 mmHg. Receiver operator characteristic curves identified optimal sit-to-stand cut-offs and the area under the curve was calculated. Results: Amongst the 994 subjects, more had systolic OH (n=404[41%]) than diastolic OH (n=349[35%]). We found that a sit-to stand systolic BP drop greater than 15 mmHg had optimal test characteristics (sensitivity=79%; specificity=89%; positive predictive value=83%; negative predictive value=86%), as did a diastolic BP drop greater than 7 mmHg (sensitivity=85%; specificity=88%; positive predictive value=79%; negative predictive value=91%). Conclusions: A sit-to-stand maneuver with lower diagnostic cut-offs for OH provides a simple OH screening test. This may be of utility in multiple clinical environments where testing could quickly be done upon patient arrival at triage or while in the clinic waiting room.
Competitiondate
201607
Approvedterm2
1 yr 0 mth
Pinamesdelim
Shaw, Brett H
Approvedterm
1 an 0 mois
Cihrcontribution2
Inst of Circ &Respiratory Hlth~ $1,000~ $0~