Grant: Discovery Grants Program - Individual
Carleton University
$26,000.00
Fire performance of durable concrete structures reinforced with Fibre Reinforced Polymer (FRP) bars
EF 2024-25
Résumé
The financial burden and the environmental impacts of replacing a large number of decaying and crumbling structures are onerous. With over 4 billion tons of cement produced annually, the cement industry produces 8% of global CO2 emissions on the planet. The highest-ever concerns regarding climate change and demands civil engineering society to seek more sustainable, durable, and long-lasting construction materials and methods. Fibre Reinforced Polymer (FRP) reinforcement is a viable alternative for the corrosion-prone steel reinforcement in reinforced concrete (RC) structures. There is adequate knowledge on FRP RC structural members at ambient temperature, and FRP reinforcement has been successfully used in many concrete structures. However, there is a lack of a holistic understanding of the fire performance of FRP RC structures in fires. The existing knowledge critically lacks extensive experimental and numerical studies which would ultimately allow moving towards generating rational, practical and detailed design guidelines for fire safety of FRP RC structures.
This proposal supports a comprehensive research program with the overarching objective of achieving an in-depth and fundamental understanding of the structural performance of FRP reinforced concrete members and structures. The long-term objective of the proposed research program is to gain fundamental understandings leading to rational and performance-based fire safety design of FRP RC structures. This program aims to ensure the fire safety of FRP RC and public safety before massive FRP RC constructions can finally be undertaken. To accomplish the long-term goals, the specific short-term objectives are to: (1) further characterize the bond behaviour of FRP reinforcing bars at high temperatures and investigate the effects of higher glass transition temperature on the bond performance; (2) conduct medium and large-scale fire tests on FRP RC structural components; and (3) extend the modelling capabilities from single-member level to a more sophisticated structural level to examine the full-frame response in fire.
The practical implications of this research program will serve the needs of Canadian as well as international codes (e.g. ACI 440.1R) for key updates. Canada has always held a leading role in developing provisions for FRP reinforcement (e.g. CSA-S6 and CSA-S806), and these codes are used around the world. The CSA-S806 uniquely has detailed provisions for fire safety design of FRP RC slabs which need to be directed towards more rational and performance-based design approaches. The current and prescriptive design guidelines recommend the thickening of concrete cover which lowers the design efficiency and requires a substantial amount of expensive FRP to be used. This research program will train 9 HQP, and they will be the future's professional engineers and researchers in Canada to fulfill the structural fire safety requirements.
Programme
Discovery Grants Program - Individual
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
RGPIN-2020-06312
Name nom
Hajiloo, Hamzeh
Department département
Civil and Environmental
Organization id
23
Institution établissement
Carleton University
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2020
Award amount
26000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1509
Committee name en
Civil, Industrial and Systems Engineering
Committee name fr
Génie civil, industriel et des systèmes
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1103
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Concrete structures
Research subject fr
Structures en béton
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
Fire performance of durable concrete structures reinforced with Fibre Reinforced Polymer (FRP) bars
Keywords
performance in fire; reinforced concrete; fibre reinforced polymer (frp); rational fire design; full-scale fire tests; structural modelling in fire; durable construction materials; properties at high temperatures; public safety; sustainability
Application summary
The financial burden and the environmental impacts of replacing a large number of decaying and crumbling structures are onerous. With over 4 billion tons of cement produced annually, the cement industry produces 8% of global CO2 emissions on the planet. The highest-ever concerns regarding climate change and demands civil engineering society to seek more sustainable, durable, and long-lasting construction materials and methods. Fibre Reinforced Polymer (FRP) reinforcement is a viable alternative for the corrosion-prone steel reinforcement in reinforced concrete (RC) structures. There is adequate knowledge on FRP RC structural members at ambient temperature, and FRP reinforcement has been successfully used in many concrete structures. However, there is a lack of a holistic understanding of the fire performance of FRP RC structures in fires. The existing knowledge critically lacks extensive experimental and numerical studies which would ultimately allow moving towards generating rational, practical and detailed design guidelines for fire safety of FRP RC structures.
This proposal supports a comprehensive research program with the overarching objective of achieving an in-depth and fundamental understanding of the structural performance of FRP reinforced concrete members and structures. The long-term objective of the proposed research program is to gain fundamental understandings leading to rational and performance-based fire safety design of FRP RC structures. This program aims to ensure the fire safety of FRP RC and public safety before massive FRP RC constructions can finally be undertaken. To accomplish the long-term goals, the specific short-term objectives are to: (1) further characterize the bond behaviour of FRP reinforcing bars at high temperatures and investigate the effects of higher glass transition temperature on the bond performance; (2) conduct medium and large-scale fire tests on FRP RC structural components; and (3) extend the modelling capabilities from single-member level to a more sophisticated structural level to examine the full-frame response in fire.
The practical implications of this research program will serve the needs of Canadian as well as international codes (e.g. ACI 440.1R) for key updates. Canada has always held a leading role in developing provisions for FRP reinforcement (e.g. CSA-S6 and CSA-S806), and these codes are used around the world. The CSA-S806 uniquely has detailed provisions for fire safety design of FRP RC slabs which need to be directed towards more rational and performance-based design approaches. The current and prescriptive design guidelines recommend the thickening of concrete cover which lowers the design efficiency and requires a substantial amount of expensive FRP to be used. This research program will train 9 HQP, and they will be the future's professional engineers and researchers in Canada to fulfill the structural fire safety requirements.