Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Idea to Innovation

University of Toronto

$15,000.00

Market Assessment of PLUM: A camera-based multimode electronic reader system

EF 2019-20

Résumé
Optical instrumentation for measurement and material characterization has become common place in settings ranging from manufacturing to the food industry to clinical labs. A key tool for optical measurement is the plate reader, which provides large-scale parallel measurement in a number of modes (e.g. absorbance, fluorescence). Imaging systems have also become standard equipment in a large number of similar environments and are heavily used in research labs (e.g. Western blot, protein/DNA gels). Despite the relatively widespread use of these instruments, their high cost and bulky/non-portable design have limited broad access to optical characterization.As we discovered as part of field work for diagnostics (Zika) trials in Latin America, there are currently no commercial options for low-cost and portable optical quantification and characterization. To meet these needs, we developed a camera-based device that we call ""PLUM"", which is essentially a lab-in-a-box that serves as a low-cost plate reader and imaging system. Our unique analysis method requires less components to operate compared to conventional absorbance mode readers. The combined hardware and software unit provides a self-contained, automated and easy-to-use system for broad applications and includes onboard data collection and analysis, incubation, cloud-based data storage (via Wi-Fi) and is capable of 8-9 hours of battery-operation. When coupled with assays of interest, our platform device can be used to detect variety of substances in fields ranging from diagnostics, agriculture to border security. Multiple copies of PLUM have been successfully deployed in Toronto, Ecuador, Brazil and Colombia for research purposes. This is an application for an I2I Market Assessment grant to reach out to the field and potential customers in order to identify ideal target markets and pain points that will inform and articulate the value proposition and market entry strategy for the successful commercialization of our technology.
Programme
Idea to Innovation
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
545076-2019
Name nom
Pardee, Keith
Department département
Pharmacy, Leslie Dan Faculty of
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2019
Competition year année de concours
2019
Award amount
15000
Program id
I2IPJ
Program name en
Idea to Innovation
Program name fr
De l'idée à l'innovation
Group en
RESEARCH PARTNERSHIPS
Group fr
PARTENARIATS DE RECHERCHE
Committee code
96
Committee name en
RPP Internal Decision Cttee
Committee name fr
Cté de décision interne - PPR
Area of application code
1101
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Human health (including medically-related psychological research)
Area of application fr
Santé publique (y compris recherche psychologique liée à la médecine)
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Installment
inst:1 - 1
Partie
1
Nb partie
1
Application title
Market Assessment of PLUM: A camera-based multimode electronic reader system
Keyword
NSERC
Application summary
Optical instrumentation for measurement and material characterization has become common place in settings ranging from manufacturing to the food industry to clinical labs. A key tool for optical measurement is the plate reader, which provides large-scale parallel measurement in a number of modes (e.g. absorbance, fluorescence). Imaging systems have also become standard equipment in a large number of similar environments and are heavily used in research labs (e.g. Western blot, protein/DNA gels). Despite the relatively widespread use of these instruments, their high cost and bulky/non-portable design have limited broad access to optical characterization.As we discovered as part of field work for diagnostics (Zika) trials in Latin America, there are currently no commercial options for low-cost and portable optical quantification and characterization. To meet these needs, we developed a camera-based device that we call ""PLUM"", which is essentially a lab-in-a-box that serves as a low-cost plate reader and imaging system. Our unique analysis method requires less components to operate compared to conventional absorbance mode readers. The combined hardware and software unit provides a self-contained, automated and easy-to-use system for broad applications and includes onboard data collection and analysis, incubation, cloud-based data storage (via Wi-Fi) and is capable of 8-9 hours of battery-operation. When coupled with assays of interest, our platform device can be used to detect variety of substances in fields ranging from diagnostics, agriculture to border security. Multiple copies of PLUM have been successfully deployed in Toronto, Ecuador, Brazil and Colombia for research purposes. This is an application for an I2I Market Assessment grant to reach out to the field and potential customers in order to identify ideal target markets and pain points that will inform and articulate the value proposition and market entry strategy for the successful commercialization of our technology.