Crack formation and control in fibre reinforced concrete structures containing conventional reinforcement
EF 2010-11
Résumé
The addition of steel fibres to concrete significantly improves the post-cracking toughness and ductility of the
material. Significant reductions in crack width and spacing can be achieved, with the fibres providing improved
control of the cracking process and preventing the occurrence of large crack widths. This enhanced tensile
behavior translates to potentially significant increases in the strength and ductility of concrete structures.
However, the use of fibre reinforced concrete (FRC) has been limited primarily to non-structural applications.
While the material holds much potential, its use in structural load-bearing elements has been slow to evolve.
One reason for this is the lack of test data, and of computational models characterizing the formation and
control of cracks, for FRC structural elements containing conventional reinforcement.
To better exploit the potential merits of this material, one must first address the question of how cracking is
controlled (vis-à-vis average crack spacings and crack widths) in FRC structural elements containing
conventional reinforcement. To this end, a three-part project is planned. An experimental investigation will be
undertaken involving the testing of thirty FRC prisms concentrically reinforced with a conventional
longitudinal reinforcing bar. A theoretical model, based on the bond characteristics of the fibres and accounting
for the influence of various controlling parameters (e.g., reinforcement ratio, fibre volume ratio, concrete
strength), will be formulated and calibrated against the test data. Verification of an existing empirical
formulation for cracking currently used by Bekaert will also be undertaken.
This project will seek to demonstrate that the inclusion of steel fibres in conventionally reinforced concrete
structural elements has beneficial effects, and will lead to improved models for quantifying the nature and
developments of cracks. This will eventually be reflected in revised design code revisions that will allow for
the use of fibre reinforcement in structural applications, first as a crack control agent and eventually as partial
or full replacement of conventional reinforcement in some applications.
Programme
Engage Grants Program
Bénéficiaire
Emplacement
Ontario, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data
Tel que publié
Application id
401818-2010
Name nom
Vecchio, Frank
Department département
Civil Engineering
Organization id
31
Institution établissement
University of Toronto
Province en
Ontario
Province fr
Ontario
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2010
Competition year année de concours
2010
Award amount
25000
Program id
EGP
Program name en
Engage Grants Program
Program name fr
Programme de subventions d'engagement partenariat
Group en
Research partnerships programs
Group fr
Programmes de partenariat
Committee code
1553
Committee name en
Ontario Internal Decision Committee
Committee name fr
Comité de décision interne pour l'Ontario
Area of application code
601
Area of application group en
Construction, urban and rural planning
Area of application group fr
Construction, urbanisme et aménagement rural
Area of application en
Structural engineering
Area of application fr
Génie des charpentes
Research subject code
1103
Research subject group en
Structural engineering
Research subject group fr
Génie des structures
Research subject en
Concrete structures
Research subject fr
Structures en béton
Partie
1
Nb partie
1
Application title
Crack formation and control in fibre reinforced concrete structures containing conventional reinforcement
Keyword
NSERC
Application summary
The addition of steel fibres to concrete significantly improves the post-cracking toughness and ductility of the
material. Significant reductions in crack width and spacing can be achieved, with the fibres providing improved
control of the cracking process and preventing the occurrence of large crack widths. This enhanced tensile
behavior translates to potentially significant increases in the strength and ductility of concrete structures.
However, the use of fibre reinforced concrete (FRC) has been limited primarily to non-structural applications.
While the material holds much potential, its use in structural load-bearing elements has been slow to evolve.
One reason for this is the lack of test data, and of computational models characterizing the formation and
control of cracks, for FRC structural elements containing conventional reinforcement.
To better exploit the potential merits of this material, one must first address the question of how cracking is
controlled (vis-à-vis average crack spacings and crack widths) in FRC structural elements containing
conventional reinforcement. To this end, a three-part project is planned. An experimental investigation will be
undertaken involving the testing of thirty FRC prisms concentrically reinforced with a conventional
longitudinal reinforcing bar. A theoretical model, based on the bond characteristics of the fibres and accounting
for the influence of various controlling parameters (e.g., reinforcement ratio, fibre volume ratio, concrete
strength), will be formulated and calibrated against the test data. Verification of an existing empirical
formulation for cracking currently used by Bekaert will also be undertaken.
This project will seek to demonstrate that the inclusion of steel fibres in conventionally reinforced concrete
structural elements has beneficial effects, and will lead to improved models for quantifying the nature and
developments of cracks. This will eventually be reflected in revised design code revisions that will allow for
the use of fibre reinforcement in structural applications, first as a crack control agent and eventually as partial
or full replacement of conventional reinforcement in some applications.