Canada Spends Logo

Explorez notre analyse du budget 2026

Grant: Discovery Grants Program - Individual

University of British Columbia

$27,000.00

Anti-biofouling mechanisms and devices for health applications

EF 2014-15

Résumé
The long-term goal of the proposed program is to continue Microelectromechanical Systems (MEMS) research in the Department of Mechanical Engineering at UBC. As part of the long-term vision, 5-year specific research themes are: (1) MEMS-based anti-biofouling devices One of the obstacles in implantable biomedical devices is ""biofouling"". The immune reaction begins by forming a thin protein layer on the device surface immediately after implantation. From the support of Discovery grant, we have demonstrated miniature piezoelectric actuators can reduce protein adsorption, the first step to prevent formation of a biofouling layer. We plan to integrate a piezoelectric device with a glucose sensor and test in vitro. (2) Application of anti-biofouling mechanisms to vascular devices Long-term vascular stents and stent grafts are commonly used to treat vascular diseases. Short and long-term stent fouling, or thrombosis presents a high risk. Protein adsorption and thrombus tissue growth on the stent is a major failure mechanism. Learning from our previous research, we hypothesize that controlled low-level vibration using magnetic micropillar arrays (MMPAs) structures with a vascular stent may promote endothelial cells to grow on the stent and reduce thrombosis tissue formation. We will develop a MMPAs and test its interaction with endothelial cells. (3) Application of anti-biofouling devices in stem cell research Differentiation of cardiomyocytes (contractile muscle cells) from iPS cells (induced pluripotent stem cells) has not been achieved in culture, even with all the stem cell reprogramming tools that are in place today. We are proposing to use the MEMS anti-biofouling devices developed in this program to apply low level cyclic strain to reprogram iPS cells into cardiomyocytes.
Programme
Discovery Grants Program - Individual
Emplacement
British Columbia, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RGPIN-2014-05492
Name nom
Chiao, Mu
Department département
Mechanical Engineering
Organization id
2
Institution établissement
University of British Columbia
Province en
British Columbia
Province fr
Colombie-Britannique
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2014
Competition year année de concours
2014
Award amount
27000
Program id
RGPIN
Program name en
Discovery Grants Program - Individual
Program name fr
Programme de subventions à la découverte - individuelles
Group en
Discovery grants programs
Group fr
Programmes de subventions à la découverte
Committee code
1512
Committee name en
Mechanical Engineering
Committee name fr
Génie mécanique
Area of application code
1102
Area of application group en
Health, education and social services
Area of application group fr
Santé publique, éducation et services sociaux
Area of application en
Biomedical engineering
Area of application fr
Génie biomédical
Research subject code
2100
Research subject group en
Mechanical engineering
Research subject group fr
Génie mécanique
Research subject en
Mechanical engineering
Research subject fr
Génie mécanique
Partie
1
Nb partie
1
Application title
Anti-biofouling mechanisms and devices for health applications
Keyword
NSERC
Application summary
The long-term goal of the proposed program is to continue Microelectromechanical Systems (MEMS) research in the Department of Mechanical Engineering at UBC. As part of the long-term vision, 5-year specific research themes are: (1) MEMS-based anti-biofouling devices One of the obstacles in implantable biomedical devices is ""biofouling"". The immune reaction begins by forming a thin protein layer on the device surface immediately after implantation. From the support of Discovery grant, we have demonstrated miniature piezoelectric actuators can reduce protein adsorption, the first step to prevent formation of a biofouling layer. We plan to integrate a piezoelectric device with a glucose sensor and test in vitro. (2) Application of anti-biofouling mechanisms to vascular devices Long-term vascular stents and stent grafts are commonly used to treat vascular diseases. Short and long-term stent fouling, or thrombosis presents a high risk. Protein adsorption and thrombus tissue growth on the stent is a major failure mechanism. Learning from our previous research, we hypothesize that controlled low-level vibration using magnetic micropillar arrays (MMPAs) structures with a vascular stent may promote endothelial cells to grow on the stent and reduce thrombosis tissue formation. We will develop a MMPAs and test its interaction with endothelial cells. (3) Application of anti-biofouling devices in stem cell research Differentiation of cardiomyocytes (contractile muscle cells) from iPS cells (induced pluripotent stem cells) has not been achieved in culture, even with all the stem cell reprogramming tools that are in place today. We are proposing to use the MEMS anti-biofouling devices developed in this program to apply low level cyclic strain to reprogram iPS cells into cardiomyocytes.