Grant: Research Tools and Instruments

McGill University

$147,238.00

In-vitro neonatal respiratory system to understand the relationship between respiratory sounds, airway pressure, and lung mechanics

EF 2024-25

Résumé
Respiratory distress is a leading cause of hospitalization in neonates. It is most commonly managed using continuous positive airway pressure (CPAP), which helps keep the airway patent and recruit the lungs, thereby decreasing airway resistance and increasing lung compliance. Successful CPAP therapy requires constant transmission of the pressure via an unobstructed circuit, but this is difficult to achieve in clinical practice. As a result, neonates often receive ineffective CPAP, which leads to clinical instability and long-term complications. Due to technological limitations, bedside assessment of pressure transmission into the lungs is not possible, and bedside tools for measuring airway resistance and lung compliance are not available for monitoring the patient's response to CPAP. As a proposed solution, respiratory sounds heard through a stethoscope are routinely used to assess airflow as part of patients' daily assessment. Those sounds can also be converted to electronic signals for further processing and analysis. We hypothesize that continuous recording and analysis of respiratory sounds can be used to predict the pressure transmitted to the lungs and the dynamic changes in airway resistance and lung compliance during CPAP therapy. The aim of this research program will be to understand the relationship between respiratory sounds (both breathing sounds and CPAP sounds), airway pressure, and the mechanical properties of neonatal lungs. To do so, equipment will be required to develop a comprehensive in-vitro neonatal respiratory system capable of evaluating this relationship. This will include a high-fidelity neonatal manikin (SimBaby TM) integrated with a breathing simulator (ASL 5000TM Lung Solution), which will allow simulating spontaneous breathing and respiratory conditions with variable airway resistances and compliances. The manikin will also be connected to a CPAP device, and will allow for measurements of breathing sounds and CPAP sounds directly from the chest via small wireless acoustic sensors. Using this system, we will conduct a series of experiments to develop models that can estimate the pressure delivered to the lungs, airway resistance, and lung compliance from respiratory sounds. Considering the invasive nature and high cost associated with pressure and lung function monitoring, we propose a unique, non-invasive alternative that only requires the monitoring of respiratory sounds to estimate airway pressure, airway resistance, and lung compliance. The equipment used in this research program will be instrumental to understanding this complex relationship in a controlled environment, and will ultimately lead to the development of an improved CPAP monitoring system that can be tested in the clinical setting. Moreover, the equipment used for this research will be used by a diverse group of students and will provide them with opportunities to acquire unique marketable skills for their future careers.
Programme
Research Tools and Instruments
Bénéficiaire
Emplacement
Quebec, Canada
Type de bénéficiaire
Academia
Type
Grant
Source
NSERC's Awards Data

Tel que publié

Application id
RTI-2024-00609
Name nom
Kearney, Robert
Department département
Pediatrics/Neonatology
Organization id
61
Institution établissement
McGill University
Province en
Québec
Province fr
Québec
Country en
CANADA
Country fr
CANADA
Fiscal year exercice financier
2024
Competition year année de concours
2024
Award amount
147238
Program id
RTI
Program name en
Research Tools and Instruments
Program name fr
Outils et instruments de recherche
Group en
DISCOVERY RESEARCH
Group fr
RECHERCHE AXÉE SUR LA DÉCOUVERTE
Committee code
1610
Committee name en
Electrical and Computer Engineering (RTI)
Committee name fr
Génie électrique et infomatique (OIR)
Area of application code
518
Area of application group en
Manufacturing processes and products
Area of application group fr
Procédés et produits industriels
Area of application en
Medical equipment and apparatus
Area of application fr
Appareils et instruments médicaux
Research subject code
1900
Research subject group en
Biomedical engineering
Research subject group fr
Génie biomédical
Research subject en
Biomedical engineering
Research subject fr
Génie biomédical
Field of research list names en
Not available
Field of research list names fr
Non disponible
Socioeconomic objective list names en
Not available
Socioeconomic objective list names fr
Non disponible
Application title
In-vitro neonatal respiratory system to understand the relationship between respiratory sounds, airway pressure, and lung mechanics
Keywords
lung simulator; continuous positive airway pressure; respiratory acoustics; lung mechanics
Application summary
Respiratory distress is a leading cause of hospitalization in neonates. It is most commonly managed using continuous positive airway pressure (CPAP), which helps keep the airway patent and recruit the lungs, thereby decreasing airway resistance and increasing lung compliance. Successful CPAP therapy requires constant transmission of the pressure via an unobstructed circuit, but this is difficult to achieve in clinical practice. As a result, neonates often receive ineffective CPAP, which leads to clinical instability and long-term complications. Due to technological limitations, bedside assessment of pressure transmission into the lungs is not possible, and bedside tools for measuring airway resistance and lung compliance are not available for monitoring the patient's response to CPAP. As a proposed solution, respiratory sounds heard through a stethoscope are routinely used to assess airflow as part of patients' daily assessment. Those sounds can also be converted to electronic signals for further processing and analysis. We hypothesize that continuous recording and analysis of respiratory sounds can be used to predict the pressure transmitted to the lungs and the dynamic changes in airway resistance and lung compliance during CPAP therapy. The aim of this research program will be to understand the relationship between respiratory sounds (both breathing sounds and CPAP sounds), airway pressure, and the mechanical properties of neonatal lungs. To do so, equipment will be required to develop a comprehensive in-vitro neonatal respiratory system capable of evaluating this relationship. This will include a high-fidelity neonatal manikin (SimBaby TM) integrated with a breathing simulator (ASL 5000TM Lung Solution), which will allow simulating spontaneous breathing and respiratory conditions with variable airway resistances and compliances. The manikin will also be connected to a CPAP device, and will allow for measurements of breathing sounds and CPAP sounds directly from the chest via small wireless acoustic sensors. Using this system, we will conduct a series of experiments to develop models that can estimate the pressure delivered to the lungs, airway resistance, and lung compliance from respiratory sounds. Considering the invasive nature and high cost associated with pressure and lung function monitoring, we propose a unique, non-invasive alternative that only requires the monitoring of respiratory sounds to estimate airway pressure, airway resistance, and lung compliance. The equipment used in this research program will be instrumental to understanding this complex relationship in a controlled environment, and will ultimately lead to the development of an improved CPAP monitoring system that can be tested in the clinical setting. Moreover, the equipment used for this research will be used by a diverse group of students and will provide them with opportunities to acquire unique marketable skills for their future careers.